Enda EI141-SM SW Universal LED display El141 0 - 20 mA/4 - 20 mA/0 - 1 V/0 - 10 V Assembly dimensions 70 x 29 mm EI141-SM SW Data Sheet

Product codes
EI141-SM SW
Page of 3
TERMS
     4 digits  7 segment yellow LED display
  ( 2 ),( 3 ),( 4 ),( 5 ) Keypad
  ( 1 ) Digital display
DIMENSIONS
CONNECTION DIAGRAM
2
1
184-253V AC 
50/60Hz 7VA
230V AC 
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100 mA 
250V AC
Neutral
Line
SUPPLY :
NOTE :
Fuse should
be connected
1) Measurement value, measurement unit, the minimum or the maximum measured values are 
    displayed in the run mode.
    Parameter name, parameter value or a user defined unit is displayed in the programming mode.
3) De
    Used for making the minimum and the maximum measured values equal in the run mode.
crement or parameter selection key in the programming mode.
2) Increment or parameter selection key in the programming mode.
    Used for displaying measurement unit or the max. measured value in the run mode.
4) Used for selecting run and programming modes,
displaying 
    measurement unit or 
 
 
 adjusting parameters, 
making the minimum and the maximum measured values equal.
9.1mm       
      Micro switch
         Character height
ENDA EI141 is intended for installation in control panels. Make sure that the device is used only for intended purpose. 
During an installation, all of the cables that are connected to the device must be free of energy. The device 
must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. All 
input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not be 
close to the power cables or components. 
The shielding must be 
grounded on the instrument side. 
The installation and electrical connections must be carried on by a qualified staff and must be 
according to the relevant locally applicable regulations.  
1) Mains supply cords shall meet the requirements of  IEC 60227 or IEC 60245. 
2) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it   should  be 
easily accessible by the operator.
Note :
Holding screw
0.4-0.5Nm 
Equipment is protected throughout
by DOUBLE INSULATION.
Panel cut-out
71mm
2
9
m
m
Panel
2
1
  -  Push up the flush-mounting 
     clamp in direction 1 as    
     shown in the figure above.
  -  Then, pull out the clamp in  
     direction 2. 
For removing mounting clamps:
Rubber
packing
Flush mounting 
clamp
Panel
Flush mounting 
clamp
 Note :  1) Panel thickness should be maximum 7 mm.
2) If there is no 60mm free space at the back 
    side of the device, it would be difficult to 
    remove it from the  panel.
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
EI141 PROGRAMMABLE INDICATOR
ENDA
 
INDUSTRIAL ELECTRONICS
2
3
0
V
 A
C
 +
1
0
%
 -
2
0
%
5
0
/6
0
H
z
  
7
V
A
IN
P
U
T
+
 
G
N
D
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
ENDA
 
INDUSTRIAL ELECTRONICS
2
4
V
 D
C
 
1
0
%
7
V
A
±
IN
P
U
T
+
 
G
N
D
EI141-24DC PROGRAMMABLE INDICATOR
+
 
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
EI141-24AC PROGRAMMABLE INDICATOR
ENDA
 
INDUSTRIAL ELECTRONICS
2
4
V
 A
C
 +
1
0
%
 -
2
0
%
5
0
/6
0
H
z
  
 7
V
A
IN
P
U
T
+
 
G
N
D
2./3     EI141-E
SET
SET
 EI141
ENDA
PROGRAMMABLE INDICATOR
SET
SET
 EI141
ENDA
PROGRAMMABLE INDICATOR
3
5
m
m
77mm
SN
: X
XX
XX
XX
XX
EI1
41
-2
30
VA
C
PR
OG
RA
MM
AB
LE
 IN
DIC
AT
OR
EN
DA
 
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
1
2
3
4
5
6
7
8
9
10
11
12
2
3
0
V
 A
C
 +
1
0
%
-2
0
%
 
5
0
/6
0
H
z
   
7
V
A
IN
P
U
T
+
 
G
N
D
2
71mm
5mm