Chauvin Arnoux P01157060 Simple Data Logger P01157060 User Manual

Product codes
P01157060
Page of 172
SIMPLE LOGGER II 
 
 
 
English 
 
 
Page 62 
4.10.2 Application Examples 
Rain Gauge : 
 
Each time a tipping bucket fills and tips, a contact opens indicating that 0.1 inch of rain has filled the bucket. 
Attaching the L404 to this contact allows recording of both the number of times the bucket has tipped, as well 
as the totalization of rainfall during the recording. 
 
In the configuration menu, the user has the ability to program both the weight and value of an event pulse. In 
this case, the weight would be 0.1 and the value would be in inches. 
 
In the Figure 4-2, eight tips occurred for a total of 0.8 inches of rainfall. 
 
Sequencing: 
 
In a processing plant it has been determined that timing on several positions is out of specification. The 
service staff needs to know the sequence of valve opening and closing, and the duration of each, to correct 
the problem. The L404 can be connected to four valves in the process and keep track of the time and 
duration of each opening and closing, thus providing the technician with the data they need to solve the 
sequence issue. 
 
In the example below we can see that the valve 1 opened and closed several times during a one minute 
period, but valves 2, 3 and 4 did not respond. 
 
 
Figure 4-2