SIMPLE LOGGER II 
 
 
 
English 
 
 
Page 57 
4.4  Recording of data 
 
 
NOTE: The Simple Logger
®
 II must first be configured for recording (see the chapter on 
 
configuring the Simple Logger
®
 II in the DataView
®
 software manual). 
 
 
Once the configuration has been transmitted to the device, the logger is ready to start the programmed 
recording. 
When data have been stored in memory, the operator can transfer them to a hard disc (see the section on 
the downloading of data in the DataView
®
 software manual). 
 
 
NOTE: A programmed recording will start even if the Simple Logger
®
 II is off. 
 
 
4.4.1  Starting recording 
 
 
NOTE: Recording cannot start if the memory is full. 
 
 
1.  Connect the device to the source to be measured; 
2.  Make sure that the logger is in standby mode (see § 4.3); 
3.  Press the "PRESS" button until the green start LED lights, then release; 
4.  The green LED indicates recording in progress by a double flash every 5 seconds; 
 
4.4.2  Stopping recording 
 
1.  Press the "PRESS" button until the orange stop LED lights, then release; 
2.  The green LED indicates the standby status by emitting a single flash rather than a double flash every 5 
seconds. 
 
The measurement data remain stored even if the device is switched off. The data are recorded in Flash 
memory, which requires no power (no losses of data even without a battery). The data can then be 
transferred to a desktop computer. 
4.5  Downloading recorded data 
 
The measurement results stored in the device are transferred to the computer using the "download" 
command on the control panel of the Simple Logger
®
  II. Additional instructions are available in the 
"Download recorded data" section of the DataView
®
 software manual.