Weigel WPM-770 V6 F1 P1 Mains-analysis device, Mains analyser 6790012 Data Sheet

Product codes
6790012
Page of 6
Data Sheet
679.D.141.02
Digital Multifunctional
Power Meter
with LCD Display and
Optional Modules
4 Quadrants Measurement
0
0
+1
-1
capacitive
motor/
import
inductive
motor/
import
capacitive
generator/
export
inductive
generator/
export
Reactive energy
+90°
-90°
Active energy
ϕ
±180°
cos 
ϕ
Q1
Q2
Q3
Q4
Auxiliary Supply
auxiliary voltage
85 ... 265 V AC (45 ... 65 Hz) / 85 ... 265 V DC
power consumption <10 VA
Environmental
operating temperature –10 ... +55
°C
range
storage temperature
–40 ... +70
°C
range
relative humidity
5% ... 95% non-condensing
Status Inputs
WPM 770 is equipped with three status inputs which can be used, e.g. for
recording switch positions. The status inputs must be connected by
switch contacts and an external supply of 80 ... 265 V AC.
Relay Outputs
WPM 770 is equipped with two relay outputs for setpoints.
switching capacity
250 V AC, 5 A / 30 V DC, 5 A
setpoints
upper and lower setpoint adjustable 0 ... 120%
delay
on - delay and off - delay adjustable 0 ... 99 s
measuring unit
selectable from 28 measuring units
RS485 Interface
WPM 770 is equipped with one RS485 interface.
protocol
MODBUS–RTU
baud rate
2400, 4800, 9600, 19200
address
1 ... 247
Beispiel
WPM 770
WPM 770
WPM 770
Standards
EN 55022
Information technology equipment – 
Radio disturbance characteristics – 
Limits and methods of measurement
EN 55024
Information technology equipment – 
Immunity characteristics – 
Limits and methods of measurement
EN 60950–1
Information technology equipment – Safety – 
Part 1: General requirements
EN  61000–3
Electromagnetic compatibility (EMC) – Limits –
–2
Part 3–2: Limits for harmonic current emissions
(equipment input current <= 16 A per phase)
–3
Part 3–3: Limitation of voltage changes, 
voltage fluctuations and flicker in public 
low–voltage supply systems, for equipment 
with rated current <= 16 A per phase and 
not subject to conditional connection
IEC 61000–4
Electromagnetic compatibility (EMC) – 
Testing and measurement techniques –
–2
Part 4–2: Electrostatic discharge 
immunity test.
–3
Part 4–3: Radiated, radio–frequency, 
electromagnetic field immunity test
–4
Part 4–4: Electrical fast transient/burst 
immunity test
–5
Part 4–5: Surge immunity test
–6
Part 4–6: Immunity to conducted disturbances, 
induced by radio–frequency fields
–8
Part 4–8: Power frequency magnetic field 
immunity test
–11
Part 4–11: Voltage dips, short interruptions 
and voltage variations immunity tests
Optional Modules
WPM770–EP
2 pulse outputs
for active energy and for reactive energy
(maximum 1 module per device)
type
optocoupler open–collector, max. 50 V, 50 mA
pulse weight
depending on VT ratio and CT ratio: 
pulse count each kWh or kvarh =
= (1/pulse constant x PT x CT)
pulse constant 1000 ... 9999 programmable
pulse width
60 ... 100 ms programmable
WPM770–BA
BACnet interface
(on request)
(maximum 1 module per device)
netzwork configuration via buttons and meter display
netzwork mode
BACnet MS/TP or P1 FLN selectable
measured values
142 register available via network
WPM770–S
4 additional status inputs
(maximum 2 modules per device)
WPM770–R
2 additional relay outputs
(maximum 1 module per device)
WPM770–M
memory extension 8 MB
WPM770–AO
2 analogue outputs
(on request)
(maximum 1 module per device)
type
4 ... 20 mA
measuring unit
selectable from 13 measuring units
scaling
adjustable 1.0 ... 10.0