4.23   TECHNICAL DATA
Operating Voltage (Un)
: Please look behind the device.
Frequency
: 50 / 60 Hz
Power Consumption
: < 6 VA
Burden
: < 1 VA (Current burden)
                                                                            < 0,5 VA (Voltage burden)
Measurement Input
                  Voltage
: 1,0 - 300,0 V AC (L-N)
: 2,0 - 500,0 V AC (L-L)
                  Current
: 0,005 - 5.5 A~
Measurement Ranges
                  Voltage
: 1,0 V - 400,0 kV
                  Current
: 0,005 ... 10.000 A
                  Frequency
: 45,0 - 65,0 Hz
                Power
: 0 - 4000 M (W, VAr, VA)
                  Energy
: 0 - 99 999 999  kWh, kVArh or MWh, MVArh
Measurement Category
: CAT III
Accuracy
             Voltage, Current 
: 0.5%±2digit
             Active Power
: 1%±2digit
             Reactive, Apparent Power
: 2%±2digit
Voltage Transformer Ratio
: 1,0...4000,0
Current Transformer Ratio
: 1...5000
Connection Type
: 3P-4W, 3P-3W, ARON
Relay Outputs (2 pcs)
: 2 NO, 5A, 1250 VA
Demand Time
: 15 min.
Communication Interface
: MODBUS RTU (RS-485)
                   Baud Rate
: 1.200 - 38.400 bps
                   Address
: 1 - 247
                   Parity
: None, Even, Odd Parity
Data Logging
                   Parameters
: Choosen 28 parameters with date and time
                   Record Size
: 15000 record lines
                   Log Duration
                  (time interval between 2 records) : No, 5 - 30.000 seconds
                   Energy Record
: 1000 record lines (1 record in every 15 minutes)
                   Event
: Yes, No
                   Memory
: 1 MB Internal Memory
Digital Inputs (2 pcs)
                  Functions
: Real Time / Latch
                  Input Pulse Width
: Min. 50  ms
                  Operation Voltage
: 5...24 V DC, max. 30 V DC
Energy Pulse Outputs (2 pcs)
                  Switch Period 
: Min. 1 sec.
                  Pulse Width
: 100-2500 ms
                  Operation Current
: Max. 50 mA
                  Operation Voltage
: 5-24 V DC max. 30 V DC
Analog Voltage Output
: 0-10 V or 2-10 V
                  Load Resistance
:
5 k
Ω
                  Response Perriod
: 1 sec.
Analog Current Output
: 0-20 mA or 4-20 mA
                 Load Resistance
:
500
Ω
                 Response Perriod
: 1 sec.
Real Time Clock
: hh : mm : ss ; dd / mm / yy
Ambient Temperature
: -5°C ; +50°C
Display
: 3,6” LCD with Backlight
Dimensions
: PR19
Equipment Protection Class
: Double Insulation-Class II ( )
Box Protection Class
: IP 40
Terminal Block Protection Class
: IP 00
Box Material
: Non-flammable
Installation
: Flush mounting with rear terminals
Wire Thickness for Voltage Connection
: 2,5 mm
2
Wire Thickness for Current Connection
: 4,0 mm
2
Wire Thickness for Pulse or
Digital Input Connection 
: 1.5 
mm
2
RS-485 Connection
: Category 5 Cable (Shielded Twisted Pair)
Weight
: 0.75 kg
Installation Category
: Class II
Type
: PR 19
Package Dimensions
: 350x290x240 mm
Package Weight
: 6 kg
Pcs per Package
: 8 pcs
only for
MPR63
-22
MPR63
-42
only for
MPR63
-23
MPR63
-43
only for
MPR63
-22
MPR63
-23
only for
MPR63
-42
MPR63
-43