Fluke 1507 Insulation measuring device, 50 V, 100 V, 250 V, 500 V, 1000 V (+20 %, -0 %) 2427890 User Manual
Product codes
2427890
1507/1503
Users Manual
Users Manual
24
Model 1503
Output Voltage
Display Range Resolution Test
Current
Accuracy
±
(% of Rdg + Digits)
0.1 to 20.00 M
Ω
0.01 M
Ω
20.0 to 200.0 M
Ω
0.1 M
Ω
500 V
(0 % to + 20 %)
200 to 500 M
Ω
1
M
Ω
1 mA @ 500 k
Ω
±
(2.0 % + 5)
0.1 to 200.0 M
Ω
0.1 M
Ω
1000 V
0 % to + 20 %)
200 to 2000 M
Ω
1
M
Ω
1 mA @ 1 M
Ω
±
(2.0 % + 5)
EN61557 Specification
The following tables are a requirement for European labeling.
Measurement Intrinsic
Uncertainty Operating
Uncertainty
1
Volts
±
(2.0 % + 3)
30 %
Earth-Bond Resistance
±
(1.5 % + 3)
30 %
Insulation Resistance
Depends on test voltage and range.
See Insulation Test specifications.
30 %
1. This specification comes from the standard and indicates the maximum amount allowable by the standard.