Fluke Fluke 4325162 Data Sheet
Product codes
4325162
2 Fluke Corporation 1623-2 and 1625-2 GEO Earth Ground Testers
General
Display:1999 digit LCD
Display with special symbols, digit height 25 mm
User interface
Instant measurement through TURN and START one button concept. The only operating elements
are rotary switch and START button
Robust, water and dust resistant
Instrument is designed for tough environmental conditions (rubber protective cover, IP56)
Memory
Internal memory storage up to 1500 records accessible via USB port
Temperature ranges
Operating temperature
-10 °C to 50 °C (14 °F to 122 °F)
Storage temperature
-30 °C to +60 °C (-22 °F to +140 °F)
Temperature coefficient
± 0.1 % of reading/°C <18 °C >28 °C
Intrinsic error
Refers to the reference temperature range and is guaranteed for 1 year
Operating error
Refers to the operating temperature range and is guaranteed for 1 year
Climatic class
C1 (IEC 654-1), -5 °C to +45 °C (23° to +115° F), 5 % to 95 % RH
Protective type
IP56 for case, IP40 for battery door according to EN60529
Safety
Protection by double and/or reinforced insulation. max. 50 V to earth. IEC61010-1: 300V CAT II,
Pollution degree 2
EMC (Emission Immunity)
IEC61326-1: Portable
Quality system
Developed, designed and manufactured according to DIN ISO 9001
External voltage
V ext, max = 24 V (dc, ac < 400 Hz), measurement inhibited for higher values
V ext rejection
> 120 dB (162⁄3, 50, 60, 400 Hz)
Measuring time
Typical 6 sec.
Max. overload
250 V rms (pertains to misuse)
Auxiliary power
6 x 1.5 V alkaline (type AA LR6)
Battery life span
Typical > 3,000 measurements
Dimensions (WxHxD)
250 mm x 133 mm x 187 mm (9.75 in x 5.25 in x 7.35 in)
Weight
1.1 kg (2.43 lb) including batteries
7.6 kg (16.8 lb) including accessories and batteries in carrying case
7.6 kg (16.8 lb) including accessories and batteries in carrying case
RA 3-pole ground resistance measurement (IEC 1557-5)
Switch position
Resolution
Measuring range
Accuracy
Operating error
RA 3-pole
0.001
Ω to 10 Ω
0.020
Ω to 19.99 kΩ
± (2 % rdg + 3 d)
± (5 % rdg + 3 d)
For 2-pole measurements connect terminals H and S with the supplied connector cable.
1623-2 Specifications