Operation 
13 
R
A
 4-Pole Measurements 
To make 4-pole measurements: 
1. Select 
4 POLE function. See Figure 5.  
2.  Connect test leads.  
Connect terminals E/C1 and ES/P1 to the earth system to be measured with the 
two supplied test leads (1.5 m). Place two ground stakes in earth/dirt. Minimum 
distance between earth electrode (E/C1), probe (S/P2), and auxiliary earth (H/C2) 
should be at least 20 m. The ES test lead eliminates the influence of the test 
leads.  
Connect the stakes with the 25 m and 50 m cable reels to H/C2 and S/P2 as 
shown below. 
3. Push 
START
 indicates that a measurement is in progress. For a continuous 
measurement, continue to push the START button. 
4.   indicates a completed measurement. The result is kept on the display until a 
new measurement is started or the rotary switch is turned.