Hanna Instruments HI 98127 pH / ° C measurement equipment -2 - 16 pH HI 98127 Leaflet

Product codes
HI 98127
Page of 2
w w w . h a n n a i n s t . c o m
Hanna Instruments reserves the right to modify the design, con-
struction and appearance of its products without advance notice.
WARRANTY
WARRANTY
WARRANTY
WARRANTY
WARRANTY
HI 98127 and HI 98128 are warranted for one year
against defects in workmanship and materials when
used for their intended purpose and maintained ac-
cording to instructions. The electrode is warranted
for a period of six months. This warranty is limited to
repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack
of prescribed maintenance are not covered.
If service is required, contact the dealer from whom
you purchased the instrument. If under warranty,
report the model number, date of purchase, serial
number and the nature of the failure. If the repair is
not covered by the warranty, you will be notified of
the charges incurred. If the instrument is to be re-
turned to Hanna Instruments, first obtain a Returned
Goods Authorization Number from the Customer
Service department and then send it with shipment
costs prepaid. When shipping any instrument, make
sure it is properly packaged for complete protection.
To validate your warranty, fill out and return the
enclosed warranty card within 14 days from the date
of purchase.
All rights are reserved. Reproduction in whole or in
part is prohibited without the written consent of the
copyright owner, Hanna Instruments Inc., Woonsocket,
Rhode Island, 02895 , USA.
Instruction Manual
HI 98127 - HI 98128
Waterproof
pH & temperature meters
Dear Customer,
Thank you for choosing a Hanna product. This manual
will provide you with the necessary information for a
correct operation. Please read it carefully before
using the meter. If you need additional technical
information, do not hesitate to e-mail us at
tech@hannainst.com.
These instruments are in compliance with the
directives.
Remove the instrument from the packing material
and examine it carefully. If any damage has occurred
during shipment, immediately notify your Dealer or
the nearest Hanna Customer Service Center.
The meters are supplied with:
• 4 x 1.5V batteries
• HI 73127 pH electrode
• HI 73128 Tool to remove the pH electrode
Note: Conserve all packing material until the instru-
ment has been observed to function correctly.
Any defective item must be returned in its
original packing.
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
HI 98127 and HI 98128 are waterproof pH and
temperature meters. The housing has been com-
pletely sealed against humidity and designed to float.
All pH readings are automatically temperature com-
pensated (ATC), and temperature values can be
displayed in °C or °F units.
The meters can be calibrated at one or two points
with auto-buffer recognition and against five memo-
rized buffer values.
Measurements are highly accurate with a unique
stability indicator right on the LCD.
A low battery symbol warns the user when the batter-
ies are to be replaced. In addition the Battery Error
Prevention System (BEPS) avoids erroneous reading
caused by low voltage level by turning the meter off.
The HI 73127 pH electrode, supplied with the meters,
is interchangeable and can be easily replaced by the
user.
The stainless steel encapsulated temperature sensor
facilitates faster and more accurate temperature mea-
surement and compensation.
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
FUNCTIONAL DESCRIPTION
FUNCTIONAL DESCRIPTION
FUNCTIONAL DESCRIPTION
FUNCTIONAL DESCRIPTION
FUNCTIONAL DESCRIPTION
                                                                                                                                                                                                                                                                
1. Battery compartment
2. Liquid Crystal Display (LCD)
3. Stability indicator
4. Low battery indicator
5. ON/OFF/MODE button
6. HI 73127 pH electrode
7. Temperature sensor
8. SET/HOLD button
9. Secondary LCD
10. Primary LCD
These Instruments are
in Compliance with
CE Directives
CE DECLARATION
CE DECLARATION
CE DECLARATION
CE DECLARATION
CE DECLARATION
OF CONFORMITY
OF CONFORMITY
OF CONFORMITY
OF CONFORMITY
OF CONFORMITY
Recommendations for Users
Before using this product, make sure that it is
entirely suitable for the environment in which it is
used. Operation of this instrument in residential
areas could cause unacceptable interferences to
radio and TV equipment.
The glass bulb at the end of the electrode is sensitive
to electrostatic discharges. Avoid touching this glass
bulb at all times. During operation, ESD wrist straps
should be worn to avoid possible damage to the
electrode by electrostatic discharges.
Any variation introduced by the user to the supplied
equipment may degrade the instrument’s EMC per-
formance.
To avoid electrical shock, do not use this instrument
when voltages at the measurement surface exceed
24 VAC or 60 VDC. To avoid damages or burns, do
not perform any measurement in microwave ovens.
ACCESSORIES
ACCESSORIES
ACCESSORIES
ACCESSORIES
ACCESSORIES
HI 73127
Replaceable pH electrode
HI 73128
Tool to remove the pH electrode
HI 70004P pH 4.01 solution, 20 mL sachet (25 pcs)
HI 70006P pH 6.86 solution, 20 mL sachet (25 pcs)
HI 70007P pH 7.01 solution, 20 mL sachet (25 pcs)
HI 70009P pH 9.18 solution, 20 mL sachet (25 pcs)
HI 70010P pH 10.01 solution, 20 mL sachet (25 pcs)
HI 77400P pH 4 & 7 solutions, 20 mL sachet (5 each)
HI 7004M pH 4.01 solution, 230 mL bottle
HI 7006M pH 6.86 solution, 230 mL bottle
HI 7007M pH 7.01 solution, 230 mL bottle
HI 7009M pH 9.18 solution, 230 mL bottle
HI 7010M pH 10.01 solution, 230 mL bottle
HI 7061M Electrode cleaning solution, 230 mL bottle
HI 70300M Electrode storage solution, 230 mL bottle