Conrad Energy Alkaline Size C Battery x2 pc(s) 658020 Data Sheet

Product codes
658020
Page of 5
 
                                            PRODUCT SPECIFICATION
Product 
Alkaline battery, 1.5 volts 
Page 
2 of 5 
Size 
LR14, Baby, C 
 
 
Conrad Electronic SE, Klaus-Conrad-Straße 1, 92240 Hirschau, Germany 
Tel. 0180/5312111, Fax 0180/5312110, webmaster@conrad.de, www.conrad-energy.de, www.conrad.de 
10. Electrical 
characteristics: 
(Test environment:20
℃±2,60%±15%R.H)(Load resistance: 3.9ohms, Measure time: 0.3S) 
(All samples shall be normalized for a minimum of 8 hours at the above environment prior to measurement) 
 
OCV (V) 
CCV (V) 
SCC (A) 
Initial 
≥ 1.59 
≥ 1.50 
≥ 10 
After 12 months storage 
≥ 1.57 
≥ 1.45 
≥ 8 
Remark: OCV: Open Circuit Voltage; CCV: Close Circuit Voltage; SCC: Short Circuit Current 
 
11. 
Discharge test (service life) (Test environment: 20
℃±2,45%--75%R.H) 
Load 
3.9
Ω  3.9Ω  3.9Ω  6.8Ω  20Ω  
Discharge mode 
24h/d 
4min/h, 8h/d 1h/day 1h/day 
4hrs/day 
End voltage 
0.9V 
0.9V 0.8V 
0.9V 
0.9V 
Initial 18.0h 
18.0h 
19h 
34h 
110h 
After 12 months storage 
17.0h 
17.0h 
17.5h 
31h 
105h 
Remark: The initial discharge test shall commence within 30 days of manufacture. 
The discharge time is the minimum average duration (MAD). 
Test quantity: n=9pcs (for per discharge test) 
 
12. Discharge 
curve: 
①  3.9 ohms 24h/d to 0.9V continuous discharge curve  (Appendix 1) 
②  3.9 ohms 4min/h,8h/d to 0.9V intermittent discharge curve  ( Appendix 1) 
③  3.9 ohms, 1h/d to 0.8V intermittent discharge curve  ( Appendix 1) 
④  6.8 ohms, 1h/d to 0.9V intermittent discharge curve  (Appendix 2) 
⑤  20ohms, 4h/d to 0.9V intermittent discharge curve  (Appendix 2)