Charging phase details
Pre Analysis
The charger checks if the battery is correctly connected.  
The battery’s charge level (V) and total capacity (Ah) is 
measured to determine the correct settings for charging.
Charging
The charger starts charging the battery with constant current  
up to 14.4V (at 20°C). The charge voltage is then held constant 
at 14.4V and the charging current is reduced until it is below 
a defined level. The charge voltage then drops to 13.8V, 
before the long-term charging phase starts.
Battery voltage
>12.65V 
12.55V–12.65V 
12.45V–12.55V 
12.35V–12.45V 
4.5V–12.35V
Battery status 
95–100% 
80% 
60% 
40% 
0-20%
LED indication
All segments on 
4 segments on 
3 segments on 
2 segments on 
1 segment on 
During charging, battery charge is shown by the number of 
LEDs illuminated. The blinking segment above these LEDs 
indicates active charging. Once full battery charge is reached, 
all 5 LED segments remain illuminated. 
  If the measured battery voltage is below 4.5V, the charger 
will enter Error Mode.
Post Analysis
The charger analyses the battery again after the charging 
phase. If the charger detects an error in the battery, the warning 
triangle will flash. Post analysis can detect batteries with  
a short circuit in individual cells. This cannot be detected in 
the pre analysis. If the battery voltage drops below 12.6V 
within 2min, the charger will go into error mode. The charging 
sequence will be stopped.
Long-term charging
After the battery is fully charged, the charger will go in to Sleep 
Mode. This is indicated by all battery LEDs slowly pulsating. 
This mode has a very low power consumption. 
  After a week in Sleep Mode, the charger will wake up and 
begin a new charging cycle. 
  The charger will also wake up and start a charging cycle  
if battery voltage drops below 12.6V.