 34: RMON C
ONFIGURATION
The rmon alarm and rmon prialarm commands take effect on existing nodes 
only.
For each port, only one RMON statistics entry can be created. That is, if an 
RMON statistics entry is already created for a given port, you will fail to create 
another statistics entry with a different index for the same port.
Displaying RMON
After the above configuration, you can execute the display command in any view 
to display the RMON running status, and to verify the configuration.
RMON Configuration 
Examples
Network requirements
The switch to be tested is connected to a remote NMS through the Internet. 
Ensure that the SNMP agents are correctly configured before performing 
RMON configuration.
Create an entry in the extended alarm table to monitor the information of 
statistics on the Ethernet port, if the change rate of which exceeds the set 
threshold, the alarm events will be triggered.
Network diagram
Figure 108   Network diagram for RMON configuration
Configuration procedures
# Add the statistics entry numbered 1 to take statistics on Ethernet 1/0/1.
<4210> system-view
 
[4210] interface Ethernet 1/0/1
 
Table 280   Display RMON
Operation 
Command 
Description 
Display RMON statistics 
display rmon statistics [ 
interface-type 
interface-number |
 unit 
unit-number ] 
Available in any view. 
Display RMON history 
information 
display rmon history [ 
interface-type 
interface-number |
 unit 
unit-number ]
Display RMON alarm 
information 
display rmon alarm [ 
entry-number ]
Display extended RMON 
alarm information 
display rmon prialarm [ 
prialarm-entry-number ]
Display RMON events 
display rmon event [ 
event-entry ]
Display RMON event logs 
display rmon eventlog [ 
event-entry ]
Console port
Switch
Internet
Network port
NMS