Finder SOCKET MASTERINPUT 93.64.0.024 93.64.0.024 Data Sheet

Product codes
93.64.0.024
Page of 10
Technical data
Nominal
Coil
Operating range
Resistance Rated coil
voltage
code
consumption
U
N
U
min
U
max
R
at U
N
V
V
V
Ω
mA
5
7.005
3.5
7.5
130
38.4
12
7.012
8.4
18
840
14.2
24
7.024
16.8
36
3,350
7.1
48
7.048
33.6
72
12,300
3.9
60
7.060
42
90
19,700
3
DC coil data
Coil specifications
• When switching a resistive load (DC1) having voltage and current   
values under the curve, an electrical life of ≥  60·10
3
can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
Electromechanical relay
4
Contact specification
F 34 - Electrical life (AC) v contact current
Cycles
DC voltage (V)
DC breaking current (A)
H 34 - Maximum DC1 breaking capacity
- Max. permitted coil voltage.
- Min. pick-up voltage with coil at ambient temperature.
R 34 - DC coil operating range v ambient temperature
Insulation according to EN 61810-1
Nominal voltage of supply system
V AC 230/400
Rated insulation voltage 
V AC 250
400
Pollution degree 
3
2
Insulation between coil and contact set
Type of insulation
Reinforced 
Overvoltage category 
III
Rated impulse voltage
kV (1.2/50 μs) 6
Dielectric strength
V AC  4,000
Insulation between open contacts
Type of disconnection
Micro-disconnection
Dielectric strength
V AC/kV (1.2/50 μs) 1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2
EN 61000-4-4
level 4 (4 kV)
Surge (1.2/50 μs) on A1 - A2 (differential mode)
EN 61000-4-5
level 3 (2 kV)
Other data
Bounce time: NO/NC
ms 1/6
Vibration resistance (5…55)Hz: NO/NC
g 10/5
Shock resistance
g 20/14
Power lost to the environment 
without contact current
W 0.2
with rated current  
W 0.5
Recommended distance between relays mounted on PCB
mm ≥ 5
Resistive load - cos
ϕ = 1
Inductive load - cos
ϕ = 0.4
II-2014, www
.finder
net.com
34
SERIE S
34 Series - Ultra-Slim PCB relays
A