Panasonic DE1AL212 PCB Mount Relay 12Vdc 1 NO, SPST-NO DE1AL212 Data Sheet

Product codes
DE1AL212
Page of 4
DE (ADE)
1
ds_61101_0000_en_de: 150607D
SPECIFICATIONS
COMPACT
HIGH-INSULATION 
POLARIZED POWER RELAY
DE RELAYS 
(ADE)
VDE
mm 
inch
12.5
.492
25.0
.984
12.5
.492
FEATURES
• Conforms to VDE0631.
Insulating distance between coil and 
contacts:
Clearance Min. 8mm 
.315 inch
Creepage distance Min. 8mm 
.315 inch
• Extensive product line-up.
• Surge voltage between contact and 
coil 12 kV
• Low operating power
Nominal operating power at 200 mW 
(Single side stable, 2 coil latching)
• Compact body saves space
Size: 12.5(W) 
× 25.0(L) × 12.5(H) mm 
.492(W) 
× .984(L) × .492(H) inch
UL/CSA, VDE approved
Contact
Coil (at 20
°C, 
68
°F
)
Characteristics
Arrangement
1 Form A
1 Form A 
1 Form B
2 Form A
Contact material
AgSnO
2
 type
Initial contact resis-
tance, max. (By voltage 
drop 6V DC 1A)
30m
Ω
Rating 
(resistive 
load)
Nominal 
switching 
capacity
10A 250V AC, 
10A 30V DC
8A 250V AC, 
8A 30V DC
8A 250V AC, 
8A 30V DC
Max. 
switching 
power
2,500 VA*, 
300W
2,000 VA*, 
240W
2,000 VA*, 
240W
Max. 
switching 
voltage
440V AC, 
230V DC
440V AC, 
230V DC
440V AC, 
230V DC
Max. 
switching 
current
10A (16A)*
8A (16A)*
8A (16A)*
Min. switch-
ing capac-
ity
#1
100 mA, 5 V DC
Expected 
life (min. 
operations)
Mechanical 
(at 300cpm)
10
7
Electrical 
(at 20 cpm) 
(resistive load)
10
5
10
5
(AC) 
× 10
4
(DC)
Electrical 
(16A / 230 V 
AC resistive)*
25000
20000
Nominal operating power
Single side stable
200 mW
1 coil latching
100 mW
2 coil latching
200 mW
Max. operating speed
20 cpm (at rated load)
Initial insulation resistance*
1
Min. 1,000 M
Ω 
(at 500 V DC)
Initial 
breakdown 
voltage*
2
Between open contacts
1,000 Vrms
Between contact sets
4,000 Vrms (2 Form A, 
1 Form A 1 Form B)
Between contact and coil
5,000 Vrms
Surge voltage between contact and coil*
3
Min. 12,000 V (initial)
Operate time [Set time]*
4
Max. 10ms (typ. 5ms) 
[Max. 10ms (typ. 4ms)] 
(at 20
°C 
68
°F
)
Release time (without diode) [Reset time]*
4
Max. 5ms (typ. 2ms) 
[Max. 10ms (typ. 4ms)] 
(at 20
°C 
68
°F
)
Temperature rise (at 70
°C)*
5
Max. 50
°C
Shock resistance
Functional*
6
Min. 196 m/s
2
{20 G}
Destructive*
7
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
8
10 to 55 Hz at double 
amplitude of 2 mm
Destructive
10 to 55 Hz at double 
amplitude of 3 mm
Conditions for operation, 
transport and storage*
9
 
(Not freezing and condens-
ing at low temperature)
Ambient temp.
–40
°C to 70°C 
–40
°F to 158°F
Humidity
5 to 85% R.H.
Unit weight
 Approx. 7 g 
.25 oz
#1 This value can change due to the switching frequency, environmental conditions, 
and desired reliability level, therefore it is recommended to check this with the 
actual load.
Remarks
* 16A possible for one contact set only with max. 4000 VA switching power.
*
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of 
±1.2 × 50μs according to JEC-212-1981
*
4
Nominal operating voltage applied to the coil, excluding contact bounce time.
*
5
By resistive method
*
6
Half-wave pulse of sine wave: 11ms, detection time: 10ms.
*
7
Half-wave pulse of sine wave: 6ms
*
8
Detection time: 10ms
*
9
Refer to 6. Conditions for operation, transport and storage mentioned in