Panasonic APF30224 PCB Mount Relay 1 CO, SPDT APF30224 Data Sheet
Product codes
APF30224
PF (APF)
3
ds_61C16_0000_en_pf: 120510D
2. Specifications
REFERENCE DATA
1. Electrical life
Tested sample: APF30224
Notes: 1. Switch contacts are all on N.O. side.
2. AC 15 and DC 13 comply with IEC-60947-5-1 testing conditions.
Characteristic
Item
Specifications
Contact
Arrangement
1 Form A
1 Form C
Contact resistance (Initial)
Max. 100 m
Ω (By voltage drop 6 V DC 1A)
Contact material
AgNi type, AgNi type/Au-plated
Rating
Nominal switching capacity (resistive load)
6 A 250 V AC
Max. switching power (resistive load)
1,500 VA
Max. switching voltage
250V AC
Max. switching current
6 A (AC)
Nominal operating power
170 mW (5 to 24 V DC), 217 mW (48 V DC), 175 mW (60 V DC)
Min. switching capacity (Reference value)
*1
*1
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual
load.
load.
100 mA 5 V DC (without Au-plated), 1 mA 1 V DC (with Au-plated)
Electrical
characteristics
characteristics
Insulation resistance (Initial)
Min. 1,000M
Ω (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
(Initial)
Between open contacts
1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil
4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage
(Between contact and coil)
(Between contact and coil)
*2
*2
Wave is standard shock voltage of
±1.2×50μs according to JEC-212-1981
6,000 V (initial)
Temperature rise (at 20
°C
68
°F
)
Max. 45
°C
113
°F
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 6A.)
Operate time (at 20
°C
68
°F
)
Max. 8 ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time (at 20
°C
68
°F
)
Max. 4 ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
characteristics
Shock resistance
Functional
Min. 98 m/s
2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10
μs)
Min. 49 m/s
2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10
μs)
Destructive
Min. 980 m/s
2
(Half-wave pulse of sine wave: 11 ms.)
Vibration resistance
Functional
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10
μs.)
Destructive
10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical
Min. 5
×10
6
(at 180 cpm)
Electrical
*3
*3
For cycle lifetime, refer to “Cautions for Use 4)” in NOTES (page 5)
N.O.: Min. 5
×10
4
(at resistive load,
6 cpm and nominal switching capacity)
N.O.: Min. 5
×10
4
, N.C.: Min. 3
×10
4
(at resistive load,
6 cpm and nominal switching capacity)
Conditions
Conditions for operation, transport and storage
*4
*4
The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions” in
Conditions” in
Ambient temperature: –40
°C to +85°C
–40
°F to +185°F
;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight
Approx. 5 g
.18 oz
Load type
Voltage
Current
Ambient temperature
No. of ops.
Resistive load
250V AC
6 A
85
°C
185
°F
30,000
Inductive load
AC 15
250V AC
3 A
25
°C
77
°F
20,000
DC 13
24V DC
2 A
25
°C
77
°F
6,000
2. Max. switching capacity
Load Limit Curve
3. Coil temperature rise
Tested sample: APF30224
Measured portion: Inside the coil
Ambient temperature: 28
Measured portion: Inside the coil
Ambient temperature: 28
°C
82
°F
4. Ambient temperature characteristics
Tested sample: APF30224, 6 pcs.
400
300
200
100
10
0.1
1
5
Current [A]
DC resistive load
V
o
ltage [V]
AC resistive load
6A
0A
50
60
70
80
90
40
30
20
10
0
100
90
110
120
140
130
Coil applied voltage, %V
Temperature rise,
°
C
5
10
-20
-40
-20
0
0
20
85
60
40
-15
-10
-5
15
20
Pick-up voltage
Drop-out
voltage
voltage
Ambient
temperature,
temperature,
°
C
Rate of
change
, %