Panasonic DS2YS12 PCB Mount Relay 12Vdc 2 CO, DPDT DS2YS12 Data Sheet

Product codes
DS2YS12
Page of 3
DS2Y
1
ds_61005_0044_en_ds2y: 151106J
SPECIFICATIONS
MINIATURE RELAY
DS2Y 
RELAYS
20
.787
9.3
.366
9.9
.390
FEATURES
• 2 Form C contact
• High sensitivity-200 mW nominal operating power
• High breakdown voltage
1500 V FCC surge between open contacts
• DIP-2C type matching 16 pin IC socket
• Sealed construction
mm 
inch
Contact
Coil (polarized) (at 20
°
68
°F
)
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms, detection time: 10
μs
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10
μs
*
7
Refer to 6. Conditions for operation, transport and storage mentioned in 
Characteristics (at 20
°
68
°F
)
FCC (Federal Communication Commission) requests following standard as 
Breakdown Voltage specification.
Arrangement
2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 m
Ω
Contact material
Ag (thickness 0,1mm,
Au clad (4µm)
Rating 
(resistive)
Max. switching power
60 W, 62.5 VA
Max. switching voltage
220 V DC, 250 V AC
Max. switching current
2 A
Max. carrying current
3 A
Expected 
life (min. 
operations)
Mechanical
1
×10
8
Electrical
1 A 30 V DC
5
×10
5
2 A 30 V DC
1
×10
5
Single side 
stable
Minimum operating power
Approx. 98 mW
(147 mW: 48 V)
Nominal operating power
Approx. 200 mW
(300 mW: 48 V)
Initial insulation resistance*
1
Min. 100 M
Ω (at 500 V DC)
Initial 
breakdown 
voltage*
2
Between open contacts
750 Vrms
Between contact sets
1,000 Vrms
Between contact and coil
1,000 Vrms
FCC surge voltage
between contacts and coil
1,500 V
Operate time*
3
 (at nominal voltage)
Approx. 4 ms
Release time*
3
 (at nominal voltage)
Approx. 3 ms
Temperature rise
Max. 65
°C with nominal 
voltage across coil and at 
nominal switching capacity
Shock resistance
Functional*
4
Min. 490 m/s
2
 {50 G}
Destructive*
5
Min. 980 m/s
2
 {100 G}
Vibration resistance
Functional*
6
10 to 55 Hz
at double amplitude of 3.3 mm
Destructive
10 to 55 Hz
at double amplitude of 5 mm
Conditions for operation, 
transport and storage*
7
(Not freezing and condens-
ing at low temperature)
Ambient 
temp.
–40
°C to +70°C
–40
°F to +158°F
Humidity
5 to 85% R.H.
Unit weight
Approx. 4 g 
14 oz.
160 μs
10 μs
1500V
750V
TYPICAL APPLICATIONS
• Telecommunication equipment
• Office equipment
• Computer peripherals
• Security alarm systems
• Medical equipment
ORDERING INFORMATION
DC12 V
Operating function
Ex  DS2Y-S
R
Nil: Single side stable
Note: Standard packing: Carton: 50 pcs. Case: 500 pcs.
Coil voltage
DC 1.5, 3, 5, 6, 
9, 12, 24, 48 V
Polarity
Nil: Standard polarity
R: Reverse polarity