Panasonic S1DXMM4C10HDC24V-S Time Delay Relay, Timer, 4 changeover contacts. Switch on delay, Pulse (On-Start), Pulse (O S1DXMM4C10HDC24V-S Data Sheet

Product codes
S1DXMM4C10HDC24V-S
Page of 7
S1DXM-A/M
1
PRODUCT TYPES
1. S1DXM-A multi-range timer
No MODE switch, Operation mode (fixed): Power ON-delay
MULTI-RANGE 
ANALOG TIMER
S1DXM-A/M 
Timers
Operating voltage
Time range
Timed-out 2 Form C
Timed-out 4 Form C
Part number
Part number
12V DC
0.05 s to 10 min
S1DXM-A2C10M-DC12V
S1DXM-A4C10M-DC12V
0.2 s to 30 min
S1DXM-A2C30M-DC12V
S1DXM-A4C30M-DC12V
0.5 s to 60 min
S1DXM-A2C60M-DC12V
S1DXM-A4C60M-DC12V
0.05 min to 10 hr
S1DXM-A2C10H-DC12V
S1DXM-A4C10H-DC12V
24V DC
0.05 s to 10 min
S1DXM-A2C10M-DC24V
S1DXM-A4C10M-DC24V
0.2 s to 30 min
S1DXM-A2C30M-DC24V
S1DXM-A4C30M-DC24V
0.5 s to 60 min
S1DXM-A2C60M-DC24V
S1DXM-A4C60M-DC24V
0.05 min to 10 hr
S1DXM-A2C10H-DC24V
S1DXM-A4C10H-DC24V
24V AC
0.05 s to 10 min
S1DXM-A2C10M-AC24V
S1DXM-A4C10M-AC24V
0.2 s to 30 min
S1DXM-A2C30M-AC24V
S1DXM-A4C30M-AC24V
0.5 s to 60 min
S1DXM-A2C60M-AC24V
S1DXM-A4C60M-AC24V
0.05 min to 10 hr
S1DXM-A2C10H-AC24V
S1DXM-A4C10H-AC24V
100 to 120V AC
0.05 s to 10 min
S1DXM-A2C10M-AC120V
S1DXM-A4C10M-AC120V
0.2 s to 30 min
S1DXM-A2C30M-AC120V
S1DXM-A4C30M-AC120V
0.5 s to 60 min
S1DXM-A2C60M-AC120V
S1DXM-A4C60M-AC120V
0.05 min to 10 hr
S1DXM-A2C10H-AC120V
S1DXM-A4C10H-AC120V
200 to 220V AC
0.05 s to 10 min
S1DXM-A2C10M-AC220V
S1DXM-A4C10M-AC220V
0.2 s to 30 min
S1DXM-A2C30M-AC220V
S1DXM-A4C30M-AC220V
0.5 s to 60 min
S1DXM-A2C60M-AC220V
S1DXM-A4C60M-AC220V
0.05 min to 10 hr
S1DXM-A2C10H-AC220V
S1DXM-A4C10H-AC220V
220 to 240V AC
0.05 s to 10 min
S1DXM-A2C10M-AC240V
S1DXM-A4C10M-AC240V
0.2 s to 30 min
S1DXM-A2C30M-AC240V
S1DXM-A4C30M-AC240V
0.5 s to 60 min
S1DXM-A2C60M-AC240V
S1DXM-A4C60M-AC240V
0.05 min to 10 hr
S1DXM-A2C10H-AC240V
S1DXM-A4C10H-AC240V
UL File No.: E122222
C-UL File No.: E122222
FEATURES
1. Multiple functions built in
The operation mode and time range can 
be switched by using the MODE and 
RANGE switches on the front panel.
2. Part number consolidation
1) The lineup consists of 64 easy-to-
choose models.
2) An operation mode fixed type 
(S1DXM-A) and 4-operation mode 
switching type (S1DXM-M) are available.
3. Cadmium-free contacts used
To eliminate environmentally harmful 
chemical substances, relays with 
cadmium-free contacts are used.
4. Economically priced
1) Prices set to lower costs.
2) Further cost reduction when used with 
HJ Relay terminal socket.
5. CE marking supported
UL and C-UL approved.
06/2006