Mueller electrical installation 873010 Leaflet

Product codes
873010
Page of 1
 
 
BA 873010rlc N;DE,GB -23247- 2013.01-V01 - ED
 
 
 
  INSTRUCTION MANUAL DIMMER [RLC] 
Technical Features 
  Safetey instructions 
Supply voltage 
230 V, 50Hz   
    
CAUTION!! DANGER OF LIFE / RISK OF FIRE AND ELECTRIC SHOCK!!
 
    Installation and assembly of electrical equipment must be carried out only by professional electrician!
 
    Connect the supply voltage/frequency as stated on the product! 
    Disconnect device from power supply for wiring and installation purposes! Check power supply is disconnected! 
    Defective devices have to be put out of service immediately! 
 Warranty void if housing opened by unauthorised person! 
 The electronic circuit is protected against a wide range of external influences.  
Incorrect operating may occur if external influences exceed certain limits!
 
 Installation and assembly of electrical equipment must be in accordance with local building and electrical codes!
 
Power consumption 
3 VA 
 
Suitable type of lamps 
Incandescence and halogen lamps 
 
LOA
Incandescence, 230V Halogens &  
LV Halogens with Electronic transformer  15 – 400 W 
 
Halogens with Ferromagnetic 
transformer 
20 – 250 W 
 
Max. number of pushbuttons 
3 lighted pushbuttons & unlimited 
non-lighted pushbuttons 
 
Dimensions 
45 x 45 x 12 mm 
 
Weight 
40 g 
 
Important Note 
Permitted ambient temperature 
0º … +40ºC 
 
 
When calculating the max. loads please take into account power dissipation of transformers:. 
For conventional transformers ~ 20% power dissipation / For electronic transformers ~ 2% power dissipation 
 
For all transformers and lamps, please take into account the specifications of the manufacturer!
 
Storage temperature 
-30º … +70ºC 
 
Type of protection 
IP20 according to
 
 DIN EN 60529 
 
Conformity with Standard 
DIN EN 60669-2-1 
 
 
Description / Installation / Operation 
  Wiring Diagram 
Description  
 
Small size dimmer, for flush-mounting (e.g. behind standard pushbutton) 
 
For leading or trailing edge dimming.  
 
Automatic detection of the load type.  
 
Protected against overload and short circuit. Built-in heat protection. 
 
Controlled by pushbutton.  
 
With or without memory. 
 
Suitable for R, L & C loads:     
- Incandescent & 230V halogen lamps (R) 
- LV Halogen lamps with Ferromagnetic transformer (L)  
- LV Halogen lamps with Electronic transformer (LC) 
 For all transformers and lamps, please take into account the specifications of the manufacturer! 
 
Installation  
 CAUTION! Do not connect different types of lamps / loads to the same dimmer! 
1 Disconnect installation from power supply and check that power supply is disconnected.  
2 Install the dimmer according to the wiring diagram.  
3 Make sure the loads are connected properly and reconnect power supply. The lamps flicker.  
   (This indicates that the dimmer has done the automatic load type detection)  
4 The dimmer is ready for use. 
 
Operation  
 
Press shortly the pushbutton to switch the lamps on and off! 
=>  Switch on „No Mem“ = Lamp(s) switches on with max. brightness. 
=>  Switch on „Mem“ = Lamp(s) switches on with the brightness of the last switch off 
 
With a long press you can dim!
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 (*)Only for very inductive loads necessary 
 
Example: