Conrad Energy 6V Ah lead acid battery, 250116 Data Sheet

Product codes
250116
Page of 8
Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no.: 250116
Material Safety Data Sheet
Page 4 of 8
7. Handling and Storage
Precautions to be Taken in Handling and Storage
Store away from reactive materials, open flames and sources of ignition as defined in Section 10 – Stability and Reactivity
Data.  Store batteries in cool, dry, well-ventilated areas.  Batteries should be stored under roof for protection against adverse
weather conditions.  Avoid damage to containers.
Other Precautions
GOOD PERSONAL HYGIENE AND WORK PRACTICES ARE MANDATORY.  Refrain from eating, drinking or smoking in
work areas.
Thoroughly wash hands, face, neck and arms, before eating, drinking and smoking. Work clothes and equipment should
remain in designated lead contaminated areas, and never taken home or laundered with personal clothing.  Wash soiled
clothing, work clothes and equipment before reuse.
8. Exposure Controls and Personal Protection
Respiratory Protection (Specify Type)
None required under normal conditions. Acid/gas NIOSH approved respirator is required when the PEL is exceeded or
employee experiences respiratory irritation.
Ventilation
Store and handle in dry ventilated area.
Local Exhaust
When PEL is exceeded.
Mechanical (General)
Not Applicable
Protective Gloves
Wear rubber or plastic acid resistant gloves.
Eye Protection
ANSI approved safety glasses with side shields/face shield recommended
Other Protective Clothing or Equipment 
Safety shower and eyewash.