Optima Batteries RTS4.2, 12V Ah lead acid battery 8022500008882 8022500008882 Data Sheet

Product codes
8022500008882
Page of 5
 
Title:  
Material Safety Data Sheet for 
All Optima Batteries
 
Date: 
1/11/05 
Rev: 
Page: 
2 of 5 
File Name: 
MSDS battery 
 
IV. Health Hazard Information 
NOTE:  Under normal conditions of use, this product does not present a health hazard.  The following information is 
provided for battery electrolyte (acid) and lead for exposure that may occur during battery production or container 
breakage or under extreme heat conditions such as fire
  
ROUTES AND METHODS OF ENTRY
 
Inhalation 
Acid mist may be generated during battery overcharging and may cause respiratory irritation.  Seepage of acid from 
broken batteries may present inhalation exposure in a confined area.
 
Skin Contact 
Battery electrolyte (acid) can cause severe irritation, burns and ulceration.
 
Skin Absorption
 
Skin absorption is not a significant route of entry.
 
Eye Contact
 
Battery electrolyte (acid) can cause severe irritation, burns, and cornea damage upon contact.
 
Ingestion
 
Hands contaminated by contact with internal components of a battery can cause ingestion of lead/lead compounds.  
Hands should be washed prior to eating, drinking, or smoking.
 
SIGNS AND SYMPTOMS OF OVEREXPOSURE
 
Acute Effects
 
Acute effects of overexposure to lead compounds are GI (gastrointestinal) upset, loss of appetite, diarrhea, 
constipation with cramping, difficulty in sleeping, and fatigue.  Exposure and/or contact with battery electrolyte 
(acid) may lead to acute irritation of the skin, corneal damage of the eyes, and irritation of the mucous membranes of 
the eyes and upper respiratory system, including lungs.
 
Chronic Effects
 
Lead and its compounds may cause chronic anemia, damage to the kidneys and nervous system.  Lead may also 
cause reproductive system damage and can affect developing fetuses in pregnant women.  Battery electrolyte (acid) 
may lead to scarring of the cornea, chronic bronchitis, as well as erosion of tooth enamel in mouth breathers in 
repeated exposures.
 
POTENTIAL TO CAUSE CANCER
 
The National Toxicological Program (NTP) and The International Agency for Research on Cancer (IARC) have 
classified “strong inorganic acid mist containing sulfuric acid” as a Category 1 carcinogen, a substance that is 
carcinogenic to humans.  The ACGIH has classified “strong inorganic acid mist containing sulfuric acid” as an A2 
carcinogen (suspected human carcinogen).  These classifications do not apply to liquid forms of sulfuric acid or 
sulfuric acid solutions contained within a battery.  Inorganic acid mist (sulfuric acid mist) is not generated under 
normal use of this product.  Misuse of the product, such as overcharging, may result in the generation of sulfuric 
acid mist. 
 
The NTP and the IARC have classified lead as an A3 carcinogen (animal carcinogen).  While the agent is 
carcinogenic in experimental animals at relatively high doses, the agent is unlikely to cause cancer in humans 
except under uncommonly high levels of exposure.  For further information, see t
he ACGIH’s pamphlet, 1996 
Threshold Limit Values and Biological Exposure Indices.
 
EMERGENCY AND FIRST AID PROCEDURES 
Inhalation 
Not expected for product under normal conditions of use. However, if acid vapor is released due to overcharging or 
abuse of the battery, remove exposed person to fresh air. If breathing is difficult, oxygen may be administered. If 
breathing has stopped, artificial respiration should be started immediately. Seek medical attention immediately.
 
Skin 
Exposure not expected for product under normal conditions of use. However, if acid contacts skin, flush with water 
and mild soap. If irritation develops, seek medical attention immediately.
 
Eyes 
Exposure not expected for product under normal conditions of use. However, if acid from broken battery case enters 
eyes, flush with water for at least 15 minutes.  Seek medical attention immediately.
 
Ingestion
 
Not expected due to physical form of finished product. However, if internal components are ingested: 
Lead/Lead compounds: Consult a physician immediately for medical attention. 
Battery Electrolyte (Acid):  Do not induce vomiting.  Refer to a physician immediately for medical attention.
 
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
 
Inorganic lead and its compounds can aggravate chronic forms of kidney, liver, and neurologic diseases.  Contact of 
battery electrolyte (acid) with the skin may aggravate skin diseases such as eczema and contact dermatitis.