CBT 12XS BATTERY TESTER   
 
A battery diagnosis device for testing all types of 12V batteries 
TEST PROCEDURES / OPERATING INSTRUCTIONS 
 
IMPORTANT : 
1.
  For testing 12 volts batteries with capacity range (CCA: A-value on 
the battery): 
SAE : 200~1200 CCA 
DIN : 110~670 CCA 
IEC : 130~790 CCA 
EN : 185~1125 CCA 
CA(MCA) : 240~1440 CA(MCA) 
2.
  Suggested operation range 0℃  (32℉) to 50℃  (122℉) in ambient 
temperature. 
 
WARNING : 
1.
  Working in the vicinity of a battery is dangerous. Batteries generate 
explosive gases during normal battery operation. For this reason, it 
is  of  utmost  importance,  if  you  have  any  doubt,  that  each  time 
before using your tester, you read these instructions very carefully. 
2.
  To reduce risk of battery  explosion, follow these instructions and 
those  published  by  the  battery  manufacturer  and  manufacturer  of 
any  equipment  you  intend  to  use  in  the  vicinity  of  the  battery. 
Observe cautionary markings on these items. 
3.
  Do not expose the tester to rain or snow.