Phoenix Contact Repeater power supply MINI MCR-SL-RPS-I-I-SP 2864752 2864752 Data Sheet

Product codes
2864752
Page of 10
Nov 14, 2013    2 / 10
Technical data
Input data
Current input signal
0 mA ... 20 mA (isolator operation)
Max. input current
28 mA
Input resistance current input
approx. 50 Ω
Transmitter supply voltage
(U
- max. 4.5 V for load 0 mA ... 20 mA)
Transmitter supply voltage range
14.7 V DC ... 25.5 V DC
Output data
Output name
Current output
Current output signal
4 mA ... 20 mA (repeater power supply and isolator operation)
Current output signal
0 mA ... 20 mA (isolator operation)
Max. output current
28 mA
Load/output load current output
≤ 500 Ω (at I = 20 mA)
Power supply
Nominal supply voltage
24 V DC
Supply voltage range
19.2 V DC ... 30 V DC (The T connector (ME 6,2 TBUS-2 1,5/5-
ST-3,81 GN, Order No. 2869728) can be used to bridge the supply
voltage. It can be snapped onto a 35 mm DIN rail according to
EN 60715))
Power consumption
< 900 mW (at 24 V DC and in repeater power supply operation)
Power consumption
< 600 mW (at 24 V DC and in isolator operation)
Connection data
Connection method
Spring-cage conn.
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section stranded min.
0.2 mm²
Conductor cross section stranded max.
2.5 mm²
Conductor cross section AWG/kcmil min.
24
Conductor cross section AWG/kcmil max
12
Stripping length
8 mm
General
No. of channels
1
Maximum transmission error
≤ 0.2 % (of final value)
Transmission error, typical
≤ 0.1 % (of final value)
Maximum temperature coefficient
< 0.01 %/K
Temperature coefficient, typical
< 0.002 %/K
Limit frequency (3 dB)
approx. 100 Hz
Step response (10-90%)
approx. 3.5 ms
Protective circuit
Transient protection
Electrical isolation
Basic insulation according to EN 61010
Surge voltage category
II
Pollution degree
2
Rated insulation voltage
50 V AC/DC