Lappkabel Data cable UNITRONIC® LiYCY A 3 x 0.5 mm² Grey 0044733 Sold per metre 0044733 Data Sheet

Product codes
0044733
Page of 1
DATA SHEET 
0044602 
 
UNITRONIC
 LiYCY  UL/CSA
 
gültig ab : 
05.02.2008
 
 
ausgearbeitet von:
 
TE-K:      Petra Samek 
Dokument: 
DB0044602_3EN 
Blatt 1 von 1 
 
Nr.: 0019/0894 
 
 
Application 
 
UNITRONIC LiYCY UL/CSA is a flexible cable with UL and CSA approval. UNITRONIC LiYCY UL/CSA is 
for internal and external wiring of electronic components, equipments and plants, especially for the export to 
North American markets or to countries in which cables approved by UL/CSA are in extended use.  
The cable is for flexible use and for static laying in dry and damp interiors intended, but not for use outside 
and in power chains. 
 
Design 
 
Conductor 
multiple wire strands of tinned copper wires  
 
  
 
 
  
UL Style 1061    
AWG 26,  0,14 mm
2
  
(7 x 0,16) 
 
 
   
 
 
 
AWG 24,  0,23 mm
2
  
(7 x 0,2) 
 
 
   
 
 
   
UL Style 1007   
AWG 22,  0,34 mm
2
  
(7 x 0,25) 
 
 
 
 
 
 
AWG 20,  0,5 mm
2
  
(7 x 0,3) 
 
 
 
 
 
 
AWG 19,  0,75 mm
2
  
(19 x 0,22) 
 
 
 
 
 
 
AWG 18,  1,0 mm
2
  
(19 x0,254) 
 
 
 
 
 
 
AWG 16,  1,5 mm
2
  
(19 x 0,32)  
 
 
Insulation 
 
Semi-Rigid PVC  
AWG 26, bis AWG 24   
 
 
UL Class 12 PVC  
AWG 22, bis AWG 16   
 
Coding 
to DIN 47100 
 
Stranding 
cores twisted in layers, wrapping by plastic foil 
 
Screening 
braid of tinned copper, coverage approx. 85% 
 
Sheath 
PVC compound acc. to UL Class 43   
Color    
chrome grey (RAL 7005) 
 
 
Technical data 
 
Specific insulation resistance 
>20  GΩ x cm 
Operating Voltage (not for power purposes) 
   300  V 
Test voltage 
 
1500  V 
Flame propagation 
flame retardant to IEC 60 332-1-2, UL VW 1 and CSA FT 1 
Minimum bending radius 
moved 
15  x cable Ø 
Temperature range 
static 
-30 bis +80  °C 
 
 
 
 
 
 
Design and electrical characteristics similar to Standard VDE 0812 
 
Approbation 
UL Style 2464, CSA AWM I/II A,B 80°C, 300 V 
 
 
RoHS directive                    
This cabel confirms to RoHS directive (2002/95/EG)