MEAN WELL SDR-240-24 Data Sheet

Page of 3
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK CURRENT
PEAK POWER  
Note.6
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE          
Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)         
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
WORKING TEMP.          
DC OK REALY CONTACT RATINGS (max.)
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1500ms, 60ms/230VAC          3000ms, 60ms/115VAC at full load
20ms/230VAC          20ms/115VAC at full load
88 ~ 264VAC          124 ~ 370VDC
47 ~ 63Hz
89%
0.93/230VAC          0.96/115VAC at full load
1.4A/115VAC          0.7A/230VAC
29 ~ 33V
91%
56 ~ 65V
90.5%
35A/115VAC          70A/230VAC
<1mA / 240VAC
Normally w
 more than 3 
 and then shut down o/p voltage
orks within 110 ~ 150% rated output power for
seconds
14 ~ 17V
>150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down o/p voltage after 3 seconds
Protection type : Shut down o/p voltage, re-power on to recover 
95
5
 (TSW) detect on heatsink of power switch
℃± ℃
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
UL508, TUV EN60950-1 approved
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A,
SEMI F47, GL approved
-25 ~ +70
 (Refer to "Derating Curve")
60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load
20 ~ 95% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
±
0.03%/
 (0 ~ 50
)
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
289.9K hrs min.      MIL-HDBK-217F (25
)
40*125.2*113.5mm (W*H*D)
0.67Kg; 20pcs/14.4Kg/1.16CUFT
POWER FACTOR (Typ.)
SDR-120-24
SDR-120-48
24V
48V
5A
2.5A
0 ~ 5A
0 ~ 2.5A
120W
120W
7.5A
3.75A
100mVp-p
120mVp-p
24 ~ 28V
48 ~ 55V
±1.0%
±1.0%
±0.5%
±0.5%
±1.0%
±1.0%
SDR-120-12
12V
10A
0 ~ 10A
120W
15A
180W (3 sec.)
100mVp-p
12 ~ 14V
±1.0%
±0.5%
±1.0%
 Features :
SDR-120 
series
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC     O/P-DC OK:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25
/ 70% RH
ENVIRONMENT
SAFETY &
FUNCTION
EMC
(Note 4)
PROTECTION
RIPPLE & NOISE (max.)  
Note.2
VOLTAGE TOLERANCE  
Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25  of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
    EMC directives.
5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.
    In case the adjacent device is a heat source, 15mm clearance is recommended.
6. 3 seconds max., please refer to peak loading curves. 
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
120W Single Output Industrial DIN RAIL with PFC Function
High efficiency 91% and low power dissipation
150% peak load capability
Built-in active PFC function, PF>0.93
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508 (industrial control equipment) approved
EN61000-6-2(EN50082-2) industrial immunity level
Built-in DC OK relay contact
100% full load burn-in test
3 years warranty
File Name:SDR-120-SPEC   2014-10-08
GL
EMC IMMUNITY
EMC EMISSION