Panasonic DSP1-5V-F PCB Mount Relay DSP15FD Data Sheet

Product codes
DSP15FD
Page of 7
DSP
4
ds_61A05_en_dsp: 070313D
3.-(1) Coil temperature rise (1 Form A)
Tested sample: DSP1a-DC12V, 5 pcs.
3.-(2) Coil temperature rise 
(1 Form A 1 Form B)
Tested sample: DSP1-DC12V, 5 pcs.
3.-(3) Coil temperature rise (2 Form A)
Tested sample: DSP2a-DC12V, 5 pcs.
50
60
40
10
20
30
0
80
100
120
8A
0A
Coil applied voltage, %V
Coil temperature rise, 
°C
50
60
40
10
20
30
0
80
100
120
5A
0A
Coil applied voltage, %V
Coil temperature rise, 
°C
50
60
40
10
20
30
0
80
100
120
5A
0A
Coil applied voltage, %V
Coil temperature rise, 
°C
4.-(1) Operate & release time 
(without diode, 1 Form A)
Tested sample: DSP1a-DC12V, 5 pcs.
4.-(2) Operate & release time 
(without diode, 1 Form A 1 Form B)
Tested sample: DSP1-DC12V, 5 pcs.
4.-(3) Operate & release time 
(without diode, 2 Form A)
Tested sample: DSP2a-DC12V, 5 pcs.)
80
100
120
4
3
2
1
0
5
6
7
Max.
x
Max.
Min.
Coil applied voltage, %V
Operate & release time, ms
x
Min.
Operate time
Release time
80
100
110
0
1
2
3
4
5
6
7
8
9
Max.
Min.
x
x
Max.
Min.
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
80
100
120
0
1
2
3
4
5
6
7
8
9
Max.
Min.
x
x
Max.
Min.
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
4.-(4) Operate & release time 
(with diode, 1 Form A)
Tested sample: DSP1a-DC12V, 5 pcs.
4.-(5) Operate & release time 
(with diode, 1 Form A 1 Form B)
Tested sample: DSP1-DC12V, 5 pcs.
4.-(6) Operate & release time 
(with diode, 2 Form A)
Tested sample: DSP2a-DC12V, 5 pcs.
80
100
120
0
1
2
3
4
5
6
7
8
9
x
Min.
Max.
Min.
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Max.
x
80
100
110
0
1
2
3
4
5
6
7
8
9
Min.
Max.
Min.
Max.
x
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
x
80
100
120
0
1
2
3
4
5
6
7
8
9
Max.
x
Min.
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Max.
Min.
x
5.-(1) Change of pick-up and drop-out voltage 
(1 Form A)
Tested sample: DSP1a-DC12V, 5 pcs.
5.-(2) Change of pick-up and drop-out voltage 
(1 Form A 1 Form B)
Tested sample: DSP1-DC12V, 5 pcs.
5.-(3) Change of pick-up and drop-out voltage 
(2 Form A)
Tested sample: DSP2a-DC12V, 5 pcs.
-40 -20
0
20 40
60
80
50
-50
Ambient
temperature, 
°C
Pick-up voltage
Drop-out
voltage
(%)
Rate of change
-40 -20
0
20 40
60
80
50
-50
Ambient
temperature, 
°C
Pick-up voltage
Drop-out voltage
(%)
Rate of change
-40 -20
0
20 40
50
-50
Ambient
temperature, 
°C
Pick-up voltage
Drop-out
voltage
(%)
Rate of change
60
80