Panasonic TQ2SA12 PCB Mount Relay 12V 2 CO, DPDT TQ2SA12 Data Sheet

Product codes
TQ2SA12
Page of 5
TQ SMD
1
ds_61020_0004_en_tqsmd: 101006J
SPECIFICATIONS
LOW-PROFILE 
SURFACE-MOUNT RELAY
TQ SMD RELAYS
mm 
inch
5.6
.220
9
.354
14
.551
FEATURES
• Low-profile: 6 mm 
.236 inch
 
(Tape height: max. 6.5 mm 
.256 inch
)
• Tape and reel package is available as standard packing style
• Surge withstand between contacts and coil: 2,500 V
• Breakdown voltage between contacts and coil: 1,500 V
• Capacity: 2 A
• High sensitivity:
2 Form C; 140 mW power consumption (Single side stable type)
Contact
Note:
#1 This value can change due to the switching frequency, environmental conditions, 
and desired reliability level, therefore it is recommended to check this with the 
actual load. (SX relays are available for low level load switching [10V DC, 10mA 
max. level])
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
By resistive method, nominal voltage applied to the coil; contact carrying current: 
2 A.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
Nominal voltage applied to the coil, excluding contact bounce time without diode.
*
5
Half-wave pulse of sine wave: 6 ms; detection time: 10 
μs
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 
μs
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in 
Characteristics
Arrangement
2 Form C
Initial contact resistance, max. 
(By voltage drop 6 V DC 1 A)
75 m
Ω
Contact material
Au-clad AgNi type
Rating
Nominal switching capacity 
(resistive load)
2 A 30 V DC, 
0.5 A 125 V AC
Max. switching power 
(resistive load)
60 W, 62.5 VA
Max. switching voltage
220 V DC, 125 V AC
Max. switching current
2 A
Min. switching capacity 
(Reference value)
#1
10 
μA 10 mV DC
Nominal 
operating 
power
Single side stable
140 mW (1.5 to 12 V DC)
200 mW (24 V DC)
300 mW (48 V DC)
1 coil latching
70 mW (1.5 to 12 V DC)
100 mW (24 V DC)
2 coil latching
140 mW (1.5 to 12 V DC)
200 mW (24 V DC)
Expected 
life (min. 
operations)
Mechanical (at 180 cpm)
10
8
 
Electrical 
(at 20 cpm)
2 A 30 V DC 
resistive
10
5
 
1 A 30 V DC 
resistive
2
×10
5
 
0.5 A 125 V 
AC resistive
10
5
 
Initial insulation resistance*
1
Min. 1,000 M
Ω (at 500 V DC)
Initial 
breakdown 
voltage
Between open 
contacts
1,000 Vrms for 1 min.
(Detection current: 10 mA)
Between contact sets
1,500 Vrms for 1 min.
(Detection current: 10 mA)
Between contact and 
coil
1,500 Vrms for 1 min.
(Detection current: 10 mA)
Initial surge 
voltage
Between open 
contacts 
(10
×160 μs)
1,500 V (FCC Part 68)
Between contacts and 
coil (2
×10 μs)
2,500 V (Telcordia)
Temperature rise*
2
 (at 20
°C)
Max. 50
°C
Operate time [Set time]*
3
 (at 20
°C)
Max. 4 ms [Max. 4 ms]
Release time [Reset time]*
4
 
(at 20
°C)
Max. 4 ms [Max. 4 ms]
Shock resistance
Functional*
5
Min. 750 m/s
2
 {75 G}
Destructive*
6
Min. 1,000 m/s
2
 {100 G}
Vibration resistance
Functional*
7
200 m/s
2
 {20G}, 10 to 55 Hz 
at double amplitude of 3.3 mm
Destructive
294 m/s
2
 {30G}, 10 to 55 Hz 
at double amplitude of 5 mm
Conditions for 
operation, transport 
and storage*
8
 
(Not freezing and 
condensing at low 
temperature)
Ambient 
temperature
–40
°C to +85°C*
3
–40
°F to +185°F
Humidity
5 to 85% R.H.
Unit weight
Approx. 2 g 
.071 oz