Finder 65.31.8.230.0300 30 SPST-NO 230 Vac 65.31.8.230.0300 Data Sheet

Product codes
65.31.8.230.0300
Page of 6
Coil specifications
Contact specification
Nominal
Coil
Operating range
Resistance Rated coil
voltage
code
consumption
U
N
U
min
U
max
R
at U
(50Hz)
V
V
V
Ω
mA
6
8.006
4.8
6.6
4.6
367
12
8.012
9.6
13.2
19
183
24
8.024
19.2
26.4
74
90
48
8.048
38.4
52.8
290
47
60
8.060
48
66
450
37
110
8.110
88
121
1,600
20
120
8.120
96
132
1,940
18.6
230
8.230
184
253
7,250
10.5
240
8.240
192
264
8,500
9.2
400
8.400
320
440
19,800
6
AC coil data
Nominal
Coil
Operating range
Resistance Rated coil
voltage
code
consumption
U
N
U
min
U
max
R
at U
N
V
V
V
Ω
mA
6
9.006
5.1
6.6
28
214
12
9.012
10.2
13.2
110
109
24
9.024
20.4
26.4
445
54
48
9.048
40.8
52.8
1,770
27.1
60
9.060
51
66
2,760
21.7
110
9.110
93.5
121
9,420
11.7
125
9.125
106
138
12,000
10.4
220
9.220
187
242
37,300
5.8
DC coil data
F 65 - Electrical life (AC) v contact current
- Max. permitted coil voltage.
- Min. pick-up voltage with coil at ambient temperature.
- Max. permitted coil voltage.
- Min. pick-up voltage with coil at ambient temperature.
4
65 Series - Power relays 20 - 30 A
Cycles
• When switching a resistive load (DC1) having voltage and current   
values under the curve, an electrical life of ≥ 80·10
3
can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
H 65 - Maximum DC1 breaking capacity
DC breaking current (A)
DC voltage (V)
1 normally open + 1 normally closed type
1 normally open  type
R 65 - DC coil operating range v ambient temperature
R 65 - AC coil operating range v ambient temperature
Resistive load - cos
ϕ = 1
Inductive load - cos
ϕ = 0.4
limit for 1NO+1NC types