Crydom SOLID-STATE-RELAY DRTU24A06R DRTU24A06R Data Sheet

Product codes
DRTU24A06R
Page of 7
DataSheet
Solid State Relay Timer
INPUT SPECIFICATIONS
(1)
DRTx24B06
DRTx24A06
DRTxxxD06
Description
Control Voltage Range 
12-24 VAC/DC
180-280 VAC/DC
90-140 VAC/DC
Must Turn-Off Voltage
1 VAC/DC
20 VAC/DC
10 VAC/DC
Min Input Current @ Min Voltage (AC/DC) (for on-state) 
7.6/6.3 mA
(5)
7.2/7.1 mA
7.6/7.4 mA
Maximum Input Current @ Maximum Voltage
12.1/9.1 mA
(6)
9.7/9.6 mA
12.5/12.3 mA
Nominal Input Impedance 
2K (7)
25K
12K
Wire Size min-max (solid/stranded) [AWG/ IEC mm²] 
(4)
22-16 / 0.33-1.31
22-16 / 0.33-1.31
22-16 / 0.33-1.31
LED Status Indicator (Color)
Yes (green)
Yes (green)
Yes (green)
Input Terminal Screw Torque [in lb (Nm)]
4.4 (0.5)
4.4 (0.5)
4.4 (0.5)
Maximum turn-on/off time
See note 
(9)
See note 
(9)
See note 
(9)
GENERAL SPECIFICATIONS
Parameters
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
3750 Vrms
(8)
Minimum Insulation Resistance (@ 500 VDC)
10
9
 Ohm
Maximum Capacitance, Input/Output
10 pF
Ambient Operating Temperature Range
-30 to 80 °C
Ambient Storage Temperature Range
-40 to 125 °C
Weight (typical)
1.76 oz (50 g)
Housing Material
UL 94 V0 Self-extinguishing
Terminal Finish
Sulfamate Nickel
Humidity
5 - 85% Non condensing
RoHS Exemption #’s
5(a), 7(a), 7(c)-I
WIRING DIAGRAM
INPUT
CONTROL
Load
Y1
+3/A1
4/A2
+1/L1
2/T1
AC Output
TIMER
Status 
Indicator
    (+ /   )
    (– /   )
    (    )
    (    )
(10)
INPUT
CONTROL
Load
Y1
+3/A1
4/A2
+1/L1
2/T1
DC Output
TIMER
Status 
Indicator
    (+ /   )
    (– /   )
    ( + )
    ( – )
Load
Load
T1
A2
A1
Y1
L1
AC/DC CONTROL 
VOLTAGE
(Input)
AC/DC SUPPLY
(OUTPUT)
Do not forget to visit us at:
 
www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.