TE Connectivity RT314730 PCB Mount Relay 230 V/AC 16A 1 CO, SPDT 1393240-7 Data Sheet

Product codes
1393240-7
Page of 4
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information 
only to be used together 
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
1
Power PCB Relay RT1
I
1 pole 12 / 16 A, 1 CO or 1 NO contact
I
DC- or AC-coil
I
Sensitive coil 400 mW
I
5 kV / 10 mm coil-contact, reinforced insulation
I
Ambient temperature 85°C (DC-coil)
I
WG version: Product in accordance to IEC60335-1
I
RoHS compliant (Directive 2002/95/EC) 
as per product date code 0413
Applications
Boiler control, timers, garage door control, POS automation,
interface modules
F0144-B
Approvals 
V
REG.-Nr. 6106,
Z
E214025, 
B
C0786, 
S
0039110/01-02, 
F
FI 190164 A1,
H
98.4118.01
Technical data of approved types on request
Contact data  
Contact configuration
1 CO or 1 NO contact
Contact set
single contact
Type of interruption 
micro disconnection
Rated current
12 A
16 A
Rated voltage / max.switching voltage AC 
240/400 VAC
Limiting continuous current 
UL: 20 A
Maximum breaking capacity AC 
3000 VA
4000 VA
Limiting making capacity, max 4 s, df 10%
25 A
30 A
Contact material
AgNi 90/10, AgNi 90/10 gold plated
Mechanical endurance DC coil
> 30 x 10
6
cycles
AC coil
> 10 x 10
6
cycles
Rated frequency of operation with / without load 
6 / 1200 min
-1
Contact ratings
Type
Load
Cycles
RT314
16 A, 250 VAC, NO contact, 85°C, DF 10%, UL508
50x10
3
RT314
16 A, 250 VAC, NC contact, 70°C, 30min
-1
53x10
3
RT314
20 A, 250 VAC, NO contact, 85°C, UL508
6x10
3
RT314
1000 W incandescent lamp, 250 VAC
1.2x10
3
RT314
10 A, 250 VAC, cos
ϕ=0.6, CO contact, 70°C
200x10
3
RT314
5 A / 2 A, 250 VAC, cos
ϕ=1, motor, NO contact, 10min
-1
, 70°C
1.1x10
6
RT314
0.26 A / 0.01 A, 230 VAC, cos
ϕ=0.38, valve, NO contact, 25min
-1
7.6x10
6
RT314
Pilot duty A300 (NO contact), B300 (CO/NC contact), UL508
RT314
1hp @ 240 VAC, 1/2hp @ 120 VAC, NO contact, UL508
RT314
AC15, 6 A, 250 VAC, NO and NC contact, 85°C, EN60947-5-1
RT314
DC13, 2 A / 24 VDC, 0.2 A / 250 VDC, NO and NC contact, 85°C, EN60947-5-1
Coil data
Rated coil voltage range DC coil
5...110 VDC
AC coil
24...230 VAC
Coil power DC coil
typ 400 mW
AC coil
typ 0.75 VA
Operative range 
2
Coil insulation system according UL1446 
class F