Esotec Solar fountain pump Palermo 101756 Leaflet

Product codes
101756
Page of 1
Operating manual
waterpump “Palermo”
These instructions relate ONLY to this product and contain important informa-
tion for using the product for the first time. Please keep these instructions for
later reference and should always accompany the product in the event of trans-
ference to a new user.
1. Introduction
Dear Costumer,
Thank you for purchasing the solar light. With this solar light you purchased a product
manufactured according to the current state of technology.
This product fulfils all requirements of the valid European and national regula-
tions. The conformity was proved. The relevant declarations and documentati-
on are deposited with the manufacturer.
To maintain this state and guarantee a safe operation, you as the user will have to fol-
low this operating manual!
2. Safety Instructions
- In case of damages caused by not
following this operating manual, the
warranty rights will expire! We exclude
liability for any consequential damages!
- We exclude liability for property or
personal damages caused by inappropriate
handling or not following the safety instructions.
- In these cases any guarantee rights will expire.
Due to safety and admission reasons (CE) it is not allowed to arbitrarily reconstruct
and/or change the solar light.
Therefore, please keep to the operating manual.
The accident prevention rules of the association of the industrial trade cooperative
association for electric plants and working material are to be considered in industrial
environments.
3. Intended use
This submersible pump is designed for pumping water in garden ponds, fountains,
water dishes, etc. It can pump water through a hose connection or can be operated
through attached lifting tubes with water sprinklers.
A solar module or a power pack with a voltage of 6 to 9 volts can be used as the
energy source. When used with a solar module, the pump works only if enough
solar radiation strikes the solar module.
The delivery rate of the pump can be adjusted using the regulator on the front side
of the pump. The water pump has no On/Off switch. As soon as the pump is con-
nected to its power supply, it starts pumping water.
4. Installation and commissioning
1. Roll out the connecting cable of the
pump completely.
2. Place the pump in water (please note
Point 5 here).
3. Connect the lifting tubes till they project
out of the water surface. For this, first
attach the reducer to the pump.
4. You can now choose from 3 different
water nozzles or a single jet nozzle. The
multiple jet nozzle attachments are
always snapped onto the nozzle cup.
5. Alternatively, the pump can also be
used for pumping water through a hose.
For this, you just have to attach a hose
to the pumpʼs pipe.
6. Now supply power to the water pump
through a solar module. Use the enclo-
sed plug with cable (red = positive pole,
black = negative pole) for this. If you
have purchased this pump as a comple-
te solar power system, then the appro-
priate plug is already attached to the
solar module.
Note: The plug has reverse-polarity protection, no force should be used while inser-
ting. The glass of the solar module is fragile.
Caution! Risk of injury! A broken module cannot be repaired again and must be dis-
posed off in an environmental-friendly way.
7. If the pumping capacity is too high, you can reduce the amount of water. Simply
turn the regulator on the front side of the pump in clockwise direction. Please
do not use force while adjusting. The adjustment range is 45°.
5. Dry run protection
The pump is equipped as standard with a dry run protec-
tion. Two sensor points are provided on the side of the
housing for this. The pump works if these points are
under water. If a point projects out of the water, the pump
does not work.
6. Care and maintenance
For optimum performance of the pump, it must be washed occasionally with warm
water depending on the water contamination. To wash the pump, open the housing
as follows:
Note: Please do not use force while dismantling or assembling the pump. The parts
are very fragile and can break easily.
1. Disconnect the pumpʼs plug.
2. Pull the front cover of the pump forward like a slide gently (Figure 1).
3. Turn the front cover of the pump by about 45° clockwise (Figure 1) and carefully
pull the cover forward (Figure 2). Watch out for the plastic shaft and the seal while
doing this.
4. Carefully drag the impeller out of the pump (if necessary, use pliers). (Figure 3).
5. Now clean all the parts carefully with warm water.
6. Then plug the shaft with the impeller carefully into the hole of the pump. Ensure
that the shaft is fitted firmly.
7. Now place the cover carefully over the pump. Ensure that the seal is fitted proper-
ly.
8. Turn the front cover again by 45 degrees counter-clockwise into the starting posi-
tion.
9. Slide the lower part of the pump completely into the pump housing.
The pump is ready to use again.
7. Malfunction
Pump is not pumping water
- Is the pump completely submerged in water? Dry run protection (Point 5)
- Is the polarity of the supply voltage reversed? Cable colour brown = + pole,
blue = negative pole
- Is the pump dirty? Cleaning the pump, see Point 6.
8. Technical data
Operating voltage:
6 - 9 V DC
Degree of protection:
IP 68
Power consumption:
Approx. 1.5 W at 6 VDC - approx. 3.3 W at 9 VDC
Pump lift:
Max. 0.7 m at 6VDC - max. 1 m at 9 VDC
Delivery rate:
Max. 240 l/h at 6 VDC - max. 330 l/h at 9 VDC
Operating temp. range: +4 to +40°C
9. Spare parts (Figure 4)
1. White ceramic shaft:
Item No.: 911002
2. Pump impeller:
Item No.: 911003
3. Internal rubber bush:
Item No.: 911004
4. Front cover:
Item No.: 911005
5. Seal for cover:
Item No.: 911006
6. Sliding carriages with suction bases:
Item No.: 911007
7. Suction bases (4 pieces)
Item No.: 911008
8. Complete nozzle set:
Item No.: 911009
Manufacturer/Importer
esotec GmbH - Gewerbegebiet Weberschlag 9 - D-92729 Weiherhammer
Tel.-Nr: 09605-92206-0 - Fax.-Nr: 09605-92206-10 - Internet: www.esotec.de
Disposal:
Dear customer,
please cooperate in avoiding waste. When you intend to dispose of the product in
future, please consider that it contains valuable raw materials suited for recycling.
Therefore, do not dispose it of with domestic waste but bring it to a collection point
for the recycling of waste electrical and electronic equipment.
Thank you very much for your cooperation!
Copyright, esotec GmbH
!
GB
Sensorpoints
lifting tubes
water nozzles
water nozzle
reducer
lifting tubes
turn 45°
1
2
3
4
1 2
3
inside
4+5
6
7
7
Customer support:
If you have problems or questions regarding this product, simply contact us!
Monday to Friday 8 am to 12 noon and 1 pm to 4 pm.
By phone: 09605-92206-27
By e-mail for ordering spare parts: ersatzteil@esotec.de
By e-mail for questions about the product: technik@esotec.de
Product: Manufacturer Item No.: 101756