Steca Solar charge controller 12 V, 24 V 30 A Steca PR 3030 104517 User Manual

Product codes
104517
Page of 16
11
708.19 | 08.44
E)  Start the auto-test with the left button. The test expires quickly and 
automatically.
F)  If there is no error, this window is displayed 
shortly (1. sec.) Afterwards, all LCD segments 
fade in and out for 1 second. Then the auto-test 
window reappears in the display.
G)  If there is an error, an error code is displayed. 
Note the code – your Steca distributor can help 
you find the error with this information. After 
30 seconds the display returns to the auto-test 
window. During this the display flashes. 
H)  In the flashing auto-test window, press the left button again to repeat 
the test or the right button to end the test.
6.7. Serial Number Query
Each regulator has a serial number that can be que-
ried using this window. Press the right button and 
the SN display begins to flash. Now, press the left 
button to display the number. The digits are display-
ed successively: - - - 1  3 4 5 6 7 8 - - - .
Press the right button to stop or continue the display.
Note the order of the digits for the complete serial number.
7.  Error Messages
Caution! Please do not open the regulator or attempt to replace
components when troubleshooting. Improper maintenance can be
hazardous to the user and the system.
If the regulator detects errors or unauthorized operating states, it flashes 
error codes on the display. Error codes can generally be differentiated, 
whether there is a temporary malfunction, e.g. regulator overload or a more 
serious system error that can be remedied by appropriate external measures. 
Since not all errors can be simultaneously displayed, the error with the 
highest error number (priority) is displayed. If several errors are present, the 
second error code is displayed after remedying the more significant error.
The following meaning is assigned to the different error codes:
Display
Meaning
Cause / Remedy
Communication error 
with the internal 
memory (EEPROM).
Disconnect consumer, solar  
module and battery. Reinstall 
the device. If the error 
reoccurs, please contact your 
specialized dealer.
Communication error 
on the  external bus 
(6-pole edge    con-
nector).
Check the 6-pole plug-in 
connection on the edge 
connector, power supply and 
function of the external ex-
tension. If the error reoccurs, 
please contact your specialized 
dealer.
Short-circuit at the 
external temperature 
sensor.
Check the contact of the -
pole edge connector, remove 
short-circuit. Check sensor.