Arnold Rak Heating Technology Electric Floor Heating FH 2130i FH P 2130i User Manual

Product codes
FH P 2130i
Page of 5
Installation Instructions
The surface-heating elements have been tested to
 
VDE Standards in
accordance with DIN EN60335-1 and DIN EN60335-2-96.
These instructions must be read carefully before commencing the installation procedure.  Whenever work is
being  undertaken  on  this  heating  equipment  the  relevant  VDE-Regulations  must  be  readily  available  and
handed directly to the installer. These instructions relate to the Surface-heating Elements  1 square metre to
10 square meters. The manufacturer guarantees the product for a period of 10 years. This guarantee does
not include any preparatory work or replacement of surface covering material.  Installation must be carried
out  by  a  qualified  person  and  be  made  strictly  in  accordance  with  the  appropriate  Standards  and
Regulations, such as, for example, VDE 0700 - Teil(Part) 753 and VDE 0100 - Teil(Part) 701. Please pay
careful  attention  to  the  information  given  on  the  Guarantee  Card.  The  specified  entries  (measured  values
made on the completed installation) must be  recorded  on  that  Guarantee  Card.  The  manufacturer  will  not
accept  responsibility  for  any  faults  which  can  be  attributed  to  measurements  which  either  have  not  been
made and recorded at all or which have been made incorrectly.
Precautionary Measures
Care must be taken to ensure that during the course of the installation procedure no damage is caused by,
for example, falling objects, sharp objects, walking on the heating element or the like. The heating elements
are to be powered by a circuit with a fault current breaker (F-1 Protection Switch) with a release current of
30 mA.  It is necessary to mount a warning notice in the close proximity of the distribution system which fully
describes the lay-out of the heating unit. One of these plaques (about 105 x 148 mm) is required for each
heating element and the installer must enter the lay-out details of each element on the relevant plaque  (a
sketch  will  suffice).  The  heating  cable  must  not  be  shortened  or  crossed  over  itself.  The  flooring  material
covering the heating element should have the least possible resistance to the conduction of heat. Care must
be taken to ensure that the heating element is not trodden upon while the floor material is being laid. It is
also necessary to avoid laying the material over screed expansion joints. Normal practice involves using  a
control  thermostat  with  a  floor-sensor,  with  the  sensor  inserted  in  an  empty  pipe.  Please  note  that  a
defective sensor will not be replaced unless it was protected in this way. The sensor should be located close
to  the  floor  surface  and  between  two  lengths  of  heating  cable.  In  the  same  way,  the  cold  conductor
(connecting  cable)  is  also  to  be  laid  inside  a  separate  empty  pipe.  For  safety  reasons  a  switching  device
should be used which ensures an all-pole disconnection of this permanently fixed equipment.  This can be,
for example, a 2-pole F1-Protective Switch (with a 3 mm gap).
Laying Procedure
The purpose of the heating elements is to provide direct heating and to achieve  control of floor surface
temperatures. They must not be used for insertion in walls or ceilings. The individual loops of heating cable
should run parallel to one another over the floor area and they should be separated by a minimum distance
of 5 cm. The cold conductors (connection cables) must not cross over themselves. They are to run
alongside  and parallel to the heating elements from the connection socket or directly to the thermostat.
Several different heating elements can be connected in parallel to one thermostat (in a similar manner to the
connection of several light bulbs in a lighting fixture). In this situation we recommend the use of a
connection socket.
The heating elements are to be embedded in a flat, single plane within the adhesive- or filling mass. Ensure
that no air bubbles are trapped and that the glass-fibre gauze fabric lays completely flat on the floor surface
with  no  folds.  In  order  to  avoid  heat  or  energy  losses  into  the  sub-floor  and  thereby  to  ensure  optimum
heating  of  the  upper  floor  surface  the  existing  insulating  material  between  the  sub-floor  surface  and  the
heating  element  must  correspond  to  the  latest  state  of  the  technology.  Finally  there  must  be  a  minimum
distance of 30 mm between the electrical elements and  any conductive system, e.g. water-pipes.
GB