Technoline WS 6010 Wireless Solar Thermometer/ Hygrometer and Clock WS 6010 Data Sheet

Product codes
WS 6010
Page of 15
 
3
Normal Operation Mode: 
 
This mode occurs when the battery voltage is higher than 2.5V. 
 
The transmitter will measure and transmit the temperature and humidity 
data to the Solar Station every 5 seconds. 
 
If a dark environment is detected, it will measure and transmit the 
temperature every 10s. 
 
If the battery voltage is dropped lower than 2.8V, it will measure and 
transmit the temperature every 10s 
 
If battery voltage is dropped lower than 2.4V, will go into Idle mode. 
 
If the solar transmitter is placed into a dark environment for 72 hours, will 
goes into Stop mode. 
 
If the user cover the solar cell for 10 seconds and press the reset button, 
"StP" will be displayed on the LCD. Then the transmitter enters STOP 
mode. 
 
Idle Operation Mode: 
 
This mode is occurred when the battery voltage is dropped lower than 
2.4V 
 
LCD is turned off 
 
Does not perform temperature measurement and transmission 
 
If battery voltage is raised higher than 2.5V, will go into Normal mode 
 
If the solar transmitter is placed into a dark environment for 72 hours, will 
goes into Stop mode.
 
 
Stop Operation Mode: 
 
This mode is occurred when the solar transmitter is placed into a dark 
environment for 72 hours or the user cover the solar cell for 10 seconds 
and press the RESET button 
 
The transmitter is in a standby state. Without perform any operation and 
LCD is off 
 
Under a bright condition, press the reset button to wake up the transmitter 
into normal operation mode (battery voltage is higher than 2.5V). ). If the 
battery is lower than 2.4V, a “Lo” icon will be shown in the LCD for a while. 
Then the transmitter will enter the idle mode. 
 
The most power saving mode.