Calibrating, Setting, and Clearing Variables
29
Monthly ET— Sets the current month’s ET. Does not affect yearly total.
Yearly ET — Sets the current year’s total ET.
To set a weather variable’s value:
1. Select the variable you wish to change (either RAIN or ET).
2. Press and release 2ND, then press and hold SET. The variable blinks. 
3. Keep holding SET until all digits are lit and stop flashing. Release SET; only one digit is 
now blinking.
4. Press the < or > keys to select digits in the value.
5. Press the + and - keys to add to or subtract from the selected digit.
6. When you are finished, press DONE to exit.
Clearing Weather Variables Accumulations
 Calibrations
The following weather variables can be cleared:
Wind Direction—Clears the wind direction calibration.
Barometer — Clears any pressure offset used to calibrate the station. 
Note: Clearing the barometric pressure offset value also clears the elevation setting in Setup Mode. 
Daily rain—Clearing the daily rain value is reflected in the daily rain total, the last 15 
minutes of rain, the last three hours of rain sent to the forecast algorithm, the umbrella 
icon, and the monthly and yearly rain totals. Clear the daily rain total if the station acci-
dentally recorded rain when the ISS was installed or after routine cleaning and mainte-
nance.
Monthly rain — Clears the monthly rain total. Does not affect the yearly rain total.
Yearly rain — Clears the yearly rain total.
Daily ET — Clears daily ET and subtracts the old daily ET total from the monthly and 
yearly ET totals.
Monthly ET — Clears the current monthly ET total. Does not affect the yearly ET total.
Yearly ET — Clears the current yearly ET total.
Heating and Cooling Degree Days— Clears the accumulated degree day total.
To clear a single weather variable:
1. Select the weather variable. (For degree days, select outside temperature, press WxCtr until 
degree days is displayed.)
2. Press and release 2ND, then press and hold CLEAR.
The variable you’ve chosen blinks. Keep holding CLEAR until 
the value changes to zero or, in the case of the barometer, the raw 
barometer value. 
Clear All Command
This command clears all stored high and low weather data, including monthly and yearly 
highs and lows, and clears alarm settings all at once.
1. Press WIND, making sure wind speed is displayed.
2. Press 2ND then press and hold CLEAR for at least six seconds. 
3. Release CLEAR when “CLEARING NOW” displays at the bottom of the screen.