Slv LED outdoor flush mount light 0.3 W 227471 Stainless steel 227471 Data Sheet

Product codes
227471
Page of 4
Instruction Manual for LED-Waylight 
 
1.  Use as directed: 
 
This product only serves lighting purposes and may: 
-  only to be used with a voltage of 12V (transformer); only use 
conventional transformers! 
-  not to be driven on. 
-  not be exposed to strong mechanical loads or to strong contamination. 
-  only be installed and operated after a condition inspection if the 
product is dirty or has been moistened through storage. 
 
If these points named above are not adhered to, a short circuit or electrical 
shock can occour. 
 
2. Technical details: 
 
 Voltage: 
  12 
Volt 
Safety class: 
 
III 
Bulb: 
  4 
LED 
Power: 
  0,3 
Cover plate 
∅:  
7,0 
cm 
Sleeve 
∅ / H: 
 
4 / 7 cm 
Weight: 
  0,15 
kg 
 Safety 
type: 
 IP 
65 
 
 
Importer:  SLV 
Elektronik 
GmbH 
 
3. Condition: 
 
Indication for the installer: In so far as you install no completely supplied system 
(with transformer), you are considered as a "manufacturer" for the purposes of 
the low-voltage directive. In this case you are required to produce the 
conformity of the whole system and by attaching of the CE-mark to define. 
 
4. Assembly: 
 
a. Separate assembly steps: 
 
 
Pull carefully the sleeve from the LED Waylight and lead the 12 V feed line 
by the sleeve (fig. 1). 
 
The sleeve must be fitted to the ground in the same height of the ground 
and has to be fixed with suitable mounting material (e.g. silicone, fix 
concrete) into the ground (fig. 2). 
 
Connect the two connection lead of the LED Waylight with the 12 V 
connection lead of the transformer by two connection clamps. 
 
Insert the LED Waylight into the sleeve, thereby pay attention that the 
gaskets are correctly fit into the groove, so that the tightness as well as the 
firm placement of the product can be ensured (fig. 3). 
 
ATTENTION:  pay attention to a firm seat of all connections, otherwise it can 
happen that the product is no longer sufficiently safe and the adherence to the 
safety type can no longer be ensured. 
 
b. Electrical connection: 
 
The electric connection may be executed only by an electric expert who is 
familiar with the valid directives. 
The transformer must be secured against a short circuit. 
Pay attention to the fact that the power supply is not damaged in the 
ceiling/wall, e.g. by drilling, screws or strong bending. This can lead to a short 
circuit. 
 
5.  What is to do if a LED is defect or does not work? 
 
Disconnect the product from the power. The changing of a defective LED may 
be executed only by an electric expert.  
 
6.  Information for the user: 
 
Operate the product only if it is correct. Switch off the product with a 
malfunction immediately and operate this only again after examination of an 
electrical specialist.  
 
This is the case, if: 
visible damages appear. 
the product does not work. 
smoke, steam or crackling sounds appear. 
an overheating is recognisable. 
Humidity occurs in the product 
 
Repairs of the product or work on mains voltage-prominent sections may only 
be carried out by qualified electricians. 
Attention: Here exists mortal danger from an electric shock. 
 
How to avoid failure and fire risk: 
 
Provide a free air circulation - cover nothing! 
Otherwise it can come to a short circuit (fire risk). 
Never let children play unsupervised with electric products! Children can not 
always estimate dangers in dealing with electric energy correctly. 
 
7.  What else have to be consider? 
 
 Use only parts, which belong to the product! Otherwise it can be that the 
product or the installation is not sufficiently safe. 
 
Disconnect the product from the power, before you… 
• 
clean or maintain the product. 
• 
do any works on the product or their components (electric 
expert).