Gw Instek GDS-2304A 4-channel oscilloscope, Digital Storage oscilloscope, GDS-2304A Data Sheet

Product codes
GDS-2304A
Page of 2
 
Logic Analyzer Option 
DS2-8LA and DS2-16A 
 
QUICK START GUIDE
 
GW INSTEK PART NO. 82DS-23043M01
 
 
 
 
 
ISO-9001 CERTIFIED MANUFACTURER 
 
 
 
 
 
This manual contains proprietary information, which is 
protected by copyright. All rights are reserved. No part 
of this manual may be photocopied, reproduced or 
translated to another language without prior written 
consent of Good Will Corporation. 
The information in this manual was correct at the time 
of printing. However, Good Will continues to improve 
its products and therefore reserves the right to change 
the specifications, equipment, and maintenance 
procedures at any time without notice.
 
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng 
Dist., New Taipei City 236, Taiwan.
 
O
VERVIEW 
The DS2-8LA and the DS2-16LA Logic Analyzer 
options allow the GDS-2000A to be upgraded to a 
powerful mixed signal oscilloscope. These options 
include both parallel and serial bus (UART, SPI, I
2
C) 
triggering and decoding as well as powerful logic 
triggering.  
The Logic Analyzer options also take advantage of the 
GDS-2000’s segmented memory, search, automatic 
measurements, cursor functionality and the exceptional 
2M record length.   
Main Features 
Option 
Channels 
Bandwidth 
DS2-16LA 
16 
200MHz 
DS2-8LA 
200MHz 
Features 
•  500MSa/s sample rate. 
•  200MHz bandwidth.  
•  Parallel bus triggering. 
•  Serial bus triggering (UART, SPI, 
1
2
C). 
•  2M record length. 
Logic Analyzer 
Software 
Features 
•  Group channels. 
•  Custom threshold levels for each 
group of digital channels.  
•  Analog waveform function. 
•  Labels. 
Package Contents and Accessories 
Standard Accessories for DS2-8LA 
Item 
Part Number 
8-Channel Logic Analyzer Probe  GTL-08LA 
8-Channel Logic Analyzer Card 
GLA-08 
Standard Accessories for DS2-16LA 
Item 
Part Number 
16-Channel Logic Analyzer Probe  GTL-16LA 
16-Channel Logic Analyzer Card  GLA-16 
Display Overview 
Logic Analyzer Display Overview 
6
2
4
5
1
3
 
Description 
 
 
1.  Horizontal Position  2.  Trigger Status 
3.  Horizontal Status 
4.  Bottom Menu 
5.  Digital Channel/Bus 
Indicators 
6.  Analog Waveform 
Indicator 
Bus Display Overview 
9
5
7
8
4
6
1
2 3
 
Description 
 
 
1.  Bus Data 
2.  Start Bit 
3.  Stop Bit 
4.  Horizontal Position 
5.  Trigger Status 
6.  Horizontal Status 
7.  Bottom Menu 
8.  Digital Channel 
Indicators 
9.  Bus Indicator 
Setting up the Oscilloscope 
This section describes how to set up the oscilloscope 
properly including installing the logic analyzer cards, 
using the logic analyzer probes and how to access the 
functions that are included with the logic analyzer 
option.  
Installing Logic Analyzer Cards 
The logic analyzer modules need to be installed into 
the module slots on the rear panel.  
Do not insert or remove the modules with the power 
on. 
1.  Slide the tabs holding the 
module cover to the unlock 
position and then remove.  
 
2.  Install the optional module. Be sure to make sure 
that the groves on the module line-up to the slots 
in the module bay. 
 
3.  Slide the locking mechanisms back to the locked 
position. 
4.  Turn on the GDS-2000A. 
5.  The GDS-2000A is now ready to operate 
Using the Logic Analyzer Probes 
This section will describe how to connect the digital 
channels to the device under test. To use the digital 
channels the optional logic analyzer module must be 
installed.  
1.  Turn the DUT off to protect it from being short 
circuited when the probes are attached. 
2.  Insert the Logic Analyzer 
probe into the Logic 
Analyzer input. 
 
3.  Connect the ground lead (black) from the logic 
analyzer probe to the circuit ground on the DUT.  
GND
 
4.  Connect another probe lead to a point of interest 
on the circuit. Make note of which probe lead is 
connected to which point. 
5.  Repeat step 4 with any remaining probes. 
GND
Signal 1
Signal 2
. . .  
Accessing the Logic Analyzer Menu 
The Logic Analyzer menu can be accessed using the 
Option key.  
1.  Press the 

 key and select Logic Analyzer to 
access the Logic Analyzer menu.  
2.  Press the D15~D0 On/Off soft-key to activate the 
digital channels. 
 
The position of each channel can be set in 
this menu. 
 
Channels can be grouped in this menu. 
3.  Press Thresholds to set the thresholds.  
 
Thresholds can be individually set for every 
4 digital channels. I.e., D0~D3, D4~D7 and 
so on. 
 
There are 5 pre-set threshold levels in 
addition to the User-defined threshold 
setting (TTL, 5.0V CMOS, 3.3V CMOS,  
2.5V CMOS, ECL, PECL, 0V). 
4.  Press Analog Waveform to display an analog 
waveform of the digital channels. 
 
Analog waveforms can be created from 
either the D0~D7 or D8~D15 digital 
channels. 
 
Only one analog waveform can be displayed 
at a time. 
5.  Press the Height soft-key to toggle the scale of the 
digital channels. 
Using the Bus Key 
The Bus key configures the UART, SPI, I
2
C or Parallel 
buses.  
1.  Press the 

 key to access the Bus menu and 
to display the bus on the display. 
 
Only those digital channels that have been 
activated from the Logic Analyzer menu will 
be accessible from the Bus menu.  
 
Pressing the Bus key again will remove the 
bus from the display.   
UART Bus 
The UART bus menu is designed to decode RS-232 and 
other common RS-232 variants such as RS-422 and RS-
485.  
1.  Press the Bus soft-key and select UART. 
2.  Press Define Inputs to select the Tx and Rx inputs 
as well as the signal polarity.  
3.  Press Thresholds to set the thresholds.  
 
There are 5 pre-set threshold levels in 
addition to the User-defined threshold 
setting (TTL, 5.0V CMOS, 3.3V CMOS,  
2.5V CMOS, ECL, PECL, 0V). 
4.  Press the Configure to set the baud rate, data bits, 
parity and packet settings.  
5.  Press Bus Display to configure how the data is 
displayed, either hex or binary.