Chauvin Arnoux P01120409Clip-on ammeter adapter 20 mm P01120409 User Manual

Product codes
P01120409
Page of 32
9
CONTENTS
1.
Presentation ...................................................................................... 9
2.
Description ........................................................................................ 9
3.
Use ..................................................................................................... 9
4.
Characteristics ................................................................................ 10
4.1
Reference conditions ............................................................... 10
4.2
Specifications and references for ordering ............................... 10
4.3
Precision and dephasing .......................................................... 11
4.4
Conditions of use ..................................................................... 11
4.5
Dimensions and weight ........................................................... 12
4.6
Compliance with international norms ....................................... 12
5.
Maintenance .................................................................................... 12
5.1
Cleaning ................................................................................. 12
5.2
Metrological verification .......................................................... 12
6.
Guarantee ........................................................................................ 12
7.
Appendix ......................................................................................... 28
1. PRESENTATION
The MN series miniclamps are designed to measure alternating currents up
to 10 kHz, on low-powered installations, from 10 mA~ to 240 A ~. They can
be used on any multimeter or oscilloscope for the MN 60. Depending on
model (see 4.2) : single or dual calibre output, alternating current, alternating
voltage or direct voltage.
They have dual insulation or reinforced insulation and comply with interna-
tional norms, particularly IEC 1010-2-032 “ammeter clamps”. (See 4.6.)
2. DESCRIPTION
(See drawing in 7. Appendix)
Output: sockets or lead (according to model): lead length: 1.5 m and 2 m
for the MN60 model.
Ratio switch for dual calibre models.
The raised arrow on top of the unit indicates the direction of the current
flow. The current is considered to flow in the positive direction when it
flows from the current producer to the current consumer. This clamp
orientation is necessary when measuring power (measuring current in
parallel with voltage).
3. USE
Limit the measuring time between 200 and 240 A : 10 minutes on, followed
by 30 minutes off.
With the MN 08 and 09 models, do not clamp a conductor before connecting
the clamp to the corresponding measuring device. Likewise, do not
disconnect the clamp from the measuring appliance when the clamp is still
attached to the cable.
n
Before connecting the clamp to the multimeter, check that the multimeter
has an appropriate calibre.
n
Open the jaws and clamp the cable through which the current you wish
to measure is running. Roughly centre the cable in the jaws. Follow the
direction of the arrow, if so required by the application in question.
n
To read the measurement, apply the appropriate reading coefficient (See
4.2 “Input/output ratio”).
NB : for dual calibre models, select the ratio which provides the best resolution
and precision.