Gw Instek AFG-2125 Function Generator, Frequency Generator AFG-2125 Data Sheet

Product codes
AFG-2125
Page of 145
 
 
AFG-2000 Series User Manual 
110
 
Amplitude Modulation (AM) Commands 
AM Overview 
 
To successfully create an AM waveform, the following commands 
must be executed in order.  
Enable AM 
Modulation 
 
Configure Carrier 
 
Select 
Modulation 
Source 
 
Select Shape 
 
Set Modulating 
Frequency 
 
Set Modulation 
Depth 
1.  Turn on AM modulation using the 
SOURce[1]:AM:STAT ON command 
2.  Use the APPLy command to select a carrier 
waveform. Alternatively the equivalent 
FUNC, FREQ, AMPL, and DCO commands 
can be used to create a carrier waveform with 
a designated frequency, amplitude and offset. 
Sine, square or ramp can be used as the 
carrier wave. 
3.  Select an internal or external modulation 
source using the SOURce[1]:AM:SOUR 
command. 
4.  Use the SOURce[1]:AM:INT:FUNC command 
to select a Sine, Square or Ramp modulating 
waveform. For internal sources only. 
5.  Set the modulating frequency using the 
SOURce[1]:AM:INT:FREQ command. For 
internal sources only. 
6.  Set the modulation depth using the 
SOURce[1]:AM:DEPT command.