Gw Instek AFG-2025 Function Generator, Frequency Generator AFG-2025 Data Sheet

Product codes
AFG-2025
Page of 145
 
 
REMOTE INTERFACE 
123 
Frequency Sweep Commands 
Sweep Overview 
 
Below shows the order in which commands must be executed to 
perform a sweep. 
Enable Sweep 
Mode 
 
Select waveform 
shape, amplitude 
and offset 
 
Select Sweep 
Boundaries 
 
Select Sweep 
Mode 
 
Select Sweep 
Time 
 
Select the sweep 
trigger source 
1.  Turn on Sweep mode using the  
SOURce[1]: SWE:STAT ON command. 
2.  Use the APPLy command to select the 
waveform shape. Alternatively, the FUNC, 
FREQ, AMPL, and DCO commands can be 
used to create a waveform (sine, square, 
ramp) with a designated frequency, 
amplitude and offset. 
3.  Set the frequency boundaries by setting the 
start and stop frequencies.  
Start~Stop 
Use the SOURce[1]:FREQ:STAR 
and SOURce[1]:FREQ:STOP to set 
the start and stop frequencies. To 
sweep up, set the stop frequency 
higher than the start frequency. To 
sweep down, set the start 
frequency higher than the stop 
frequency.  
4.  Choose Linear or Logarithmic spacing using 
the SOURce[1]:SWE:SPAC command. 
5.  Choose the sweep time (rate) using the 
SOURce[1]:SWE:TIME command. 
6.  Select an internal or external sweep trigger 
source using the SOURce[1]:SOUR command.