Lappkabel 4520005, H07V-K 1.5 Single Core Wiring Cable, , AWG, Green-yellow Sheath 4520005 Data Sheet

Product codes
4520005
Page of 1
U.I. Lapp 
GmbH 
DATA SHEET 
 
 
 
 
 
H07V-K (X07V-K)
 
 
DB4520001EN                    
valid from: 2010-08-20
 
 
 
Originator: T. Merker / PCM 
Document: 
DB4520001EN 
page 1 of 1 
All deviations from this specification are subject to explicit consent of U.I. Lapp GmbH. All rights reserved acc. to DIN 34.  
PD 0019/2.1_11.09EN 
 
MAKE-UP TYPE 
H07V-K 
 
CERTIFICATION 
H07V-K ◄HAR► (arrowheads can be blank also) according to harmonisation document HD 21.3/VDE 0281-3 
 
APPLICATION
 
(HD 516/VDE 0298-300) 
The single-conductor cable H07V-K is a flexible, non-sheathed cable for fix, internal wiring, that is, for fixed installation in pipes on, in and 
under plaster, in closed installation channels or in similar, closed systems. But these cables mustn’t be used for direct laying on racks, 
troughs and tubes. H07V-K is suitable for protected, fix laying, in or on lighting equipment or control and switching devices for voltages up 
to 1000 V AC or up to 750 V DC to ground. Contact with water is forbidden. Basically, H07V-K can be used for the laying in rigid conduits, 
installation channels meant to be opened and closed installation channels as well as for the wiring inside of tools, devices, appliances and 
operating material, provided the normal temperature range is respected. In case of laying inside of rigid conduits, tubes, pipes, installation 
channels, the conductor temperature reached also depends on the lost heat of further H07V-K, other types of cables or mountings laid 
inside of the conduit, too, and which any single H07V-K single-conductor cable gets or could get in touch with. Moreover, the maximum 
conductor temperature truly operated of H07V-K installed inside of pipes, tubes, installation channels and conduits depends on the maxi-
mum surface and conductor temperatures of other cable types and mountings that are laid inside in parallel possibly. 
 
PERMISSIBLE VOLTAGES
 
(HD 21.1/VDE 0281-1) 
Rated, conductor-to-ground (PE) (U
0
)   
 
450 V AC/675 V DC; 600 V AC****/900 V DC**** 
Rated, conductor (not PE)-to-conductor (not PE) (U) 
750 V AC/1125 V DC; 1000 V AC****/1500 V DC**** 
Operated, conductor-to-ground (PE) (U
0
 
495 V AC/742.5 V DC; 660 V AC****/990 V DC**** 
Operated, conductor (not PE)-to-conductor (not PE) (U) 
825 V AC/1237.5 V DC; 1100 V AC****/1650 V DC**** 
 
MAKE-UP
 (HD 21.3/VDE 0281-3) 
Conductor 
 
 
 
 
Bare copper strands 
Conductor class 
 
 
 
 
Fine-wired/Class 5 according to IEC 60228/EN 60228/VDE 0295 
Cross sections in mm² 
 
 
 
1.5 to 240 
Insulation  
 
 
 
 
PVC-based compound TI 1 according to HD 21.1/VDE 0281-1 
 
 
 
 
 
 
Wall thicknesses in line with HD 21.3/VDE 0281-3 
Outer cable diameter 
 
 
 
HD 21.3/VDE 0281-3 
 
ELECTRICAL PROPERTIES AT +20 °C
 
(HD 21.3/VDE 0281-3) 
Rated voltage U
0
/U 
 
 
 
450/750 V AC 
Test voltage 
 
 
 
 
2500 V AC 
 
MECHANICAL, CHEMICAL AND THERMAL PROPERTIES 
Category temperature (HD 516/VDE 0298-300; Lapp) 
Permanent load 
 
  
 
 
+80 °C max. 
 
 
 
 
 
 
Short-to-ground (5 sec maximally) 
 
 
+160 °C max. 
 
 
 
 
 
 
Cable surface 
 
 
 
 
+70 °C max. 
 
 
 
 
 
 
Laying and handling 
 
 
 
+5 °C min. 
 
 
 
 
 
 
Ambient temperature during storage   
 
+40 °C max. 
 
 
 
 
 
 
Cable surface during storage and at direct solar radiation  +60 °C max. 
Minimum bending radii (HD 516/VDE 0298-300)  
OD* ≤ 8 mm 
 
 
 
 
4**OD*/2***OD*  
(at a cable temperature of +10 °C to +30 °C) 
 
8 mm < OD* ≤ 12 mm 
 
 
 
5**OD*/3***OD* 
 
 
 
 
 
 
OD* > 12 mm 
 
 
 
 
6**OD*/4***OD* 
Current rating 
 
 
 
 
HD 516/VDE 0298-300 
 
 
 
 
 
 
VDE 0298-4 
Cold bending up to the average OD* of 12.5 mm  
HD 21.3/VDE 0281-3; EN 60811-1-4, 8.1/VDE 0473-811-1-4, 8.1 
Cold elongation above the average OD* of 12.5 mm 
HD 21.3/VDE 0281-3; EN 60811-1-4, 8.3/VDE 0473-811-1-4, 8.3 
Heat shock 
 
 
 
 
HD 21.3/VDE 0281-3; EN 60811-3-1, 9.1/VDE 0473-811-3-1, 9.1 
Heat pressure 
 
 
 
 
HD 21.3/VDE 0281-3; EN 60811-3-1, 8.1/VDE 0473-811-3-1, 8.1 
Flame retardance   
 
 
 
HD 21.3/VDE 0281-3; IEC 60332-1-2/EN 60332-1-2/VDE 0482-332-1-2 
Ozone resistance   
 
 
 
Not ozone-resistant (insulation compound TI 1 acc. to HD 21.1/VDE 0281-1) 
European EC low voltage directive 
 
 
This cable complies with ECD 73/23/EEC (LVD – low voltage directive). 
 
* OD = outer cable diameter 
** if used H07V-K-conventionally according to HD 516/VDE 0298-300 
*** at cautious bending 
**** at fix laying with mechanical protection in switch and control stations/cabinets/systems according to HD 516/VDE 0298-300