Lappkabel 2510001, HEAT 180 FZLSi Single Core Wiring Cable, 1 (32 x 0.2) mm², AWG, Red Sheath 2510001 Data Sheet
Product codes
2510001
DATA SHEET
2510001
ÖLFLEX
®
HEAT 180 FZLSi
valid from :
10.12.2007
elaborated by:
TE-K: M. Herb / R. Krämer
Document:
DB2510001EN
page 1 of 1
Nr.: 0019/0894
Application
ÖLFLEX
HEAT 180 FZLSi are high-voltage ignition cores and recommended for use for inside wiring in the case
of raised ambient temperatures under sufficient ventilation and small mechanical stress. In the case of room tem-
perature, ÖLFLEX
perature, ÖLFLEX
HEAT 180 FZLSi is largely resistant against oil, alcohol, acids, caustic solutions, salt solu-
tions and salt water. ÖLFLEX
HEAT 180 FZLSi is UV-and weather-resistant but should be used in outside areas
only with mechanical protection.
Design
Conductor
copper strands (ca. 32x0,20 mm) acc. to IEC 60228 resp. VDE 0295, class 5
Core insulation
Silicone based compound EI2 acc. to HD 22.1 resp. VDE 0282-1
Core identification
red
Electrical properties at 20 °C
Nominal voltage
10 kV
Test voltage
20 kV AC
Mechanical and thermal properties
Temperature range
-50 °C up to +180 °C max. conductor temperature
pay attention to sufficient ventilation, if ignoring
the max. conductor temperature is +100 °C.
Min. bending radius
6 x cable diameter for fixed installation
15 x cable diameter for flex. applications
Flammability
flame retardant in acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2
after combustion a SiO2-ash skeleton remains, which has still
good insulation properties but has no more any mechanical stability.
Halogen-free
acc. to IEC 60754-1 resp. VDE 0472 part 815
Corrosivity
acc. to IEC 60754-2 resp. VDE 0482 part 267-2-3
Tests
in acc. to IEC 60811-x-x resp. VDE 0473 part 811-x-x, VDE 0472
EC directive
this cable confirms to ECD 2006/95/EC (low voltage directive).