Moxa OnCell™ G2110 GSM/GPRS Modem ONCELL G2110 Leaflet

Product codes
ONCELL G2110
Page of 2
13-38
w w w. m o x a . c o m
i n f o @ m o x a . c o m
WLAN & Cellular Solutions  
>
OnCell G2100 Series
WLAN & Cellular Solutions
13
OnCell G2100 Series
Industrial quad-band GSM/GPRS modem
Quad-band GSM/GPRS 850/900/1800/1900 MHz
 
Separate RS-232 and RS-422/485 serial interfaces (G2150I only)
 
2.5 KV RMS isolation for 1 minute for all serial signals (G2150I 
 
only)
Extended operating temperature from -30 to 75°C (G2110-T only)
 
Vertical IP30 housing with SIM card protection
 
LED indicators for GSM/GPRS, data transmission, and signal level
 
DIN-Rail and wall mounting
 
SMS Tunnel Mode provided
 
The OnCell G2100 Series of industrial quad-band GSM/GPRS modems 
are designed to transmit data and short messages (SMS) over GSM/
GPRS mobile networks. The modems can be used to increase the 
efficiency of maintenance and communication, but do not require 
detailed training. In addition, the modems can be mounted on a 
DIN-rail or wall. The OnCell G2100 modems accept a 12 to 48 VDC 
power input, making them suitable for use with a variety of field 
power sources. The serial ports feature 15 KV ESD line protection to 
protect the product from harmful electrical discharge, and separate 
RS-232 and RS-422/485 interfaces are built into the OnCell G2150I, 
each with 2.5 KV RMS isolation protection for one minute. The two 
serial interfaces on the OnCell G2150I make it ideal for attaching all 
kinds of devices, such as stand-alone controllers, PC COM ports, and 
multi-dropped electric meters. In addition, the OnCell G2110-T has 
an extended operating temperature (-40 to 75°C) design that makes it 
suitable for heavy industrial use.
Overview
Specifi cations
Cellular Interface
Standards: GSM and GPRS
Band Options: Quad-band 850/900/1800/1900 MHz
GPRS Multi-slot Class: Class 10
GPRS Terminal Device Class: Class B
GPRS Coding Schemes: CS1 to CS4
CSD Data Transmission Rate: Up to 14,400 bps
SMS: Point-to-point Text/PDU, Mobile Originated (MO) and Mobile 
Terminated (MT Cell Broadcast in accordance with GSM 07.05)
Tx Power: 1 watt GSM1800/1900, 2 watts EGSM 900/GSM 850
SIM Control: 3 V
Serial Interface
Serial Standards:
G2110: RS-232 (DB9 female connector)
G2150I: RS-232 (DB9 female connector), RS-422/485 (5-pin 
terminal block connector)
Number of Ports: 1
ESD Protection: 15 KV (G2110 only)
Optical Isolation: 2.5 KV (G2150I only)
Serial Communication Parameters
Data Bits: 7, 8
Stop Bits: 1, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS
Baudrate: 300 bps to 115.2 Kbps
Serial Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, RI, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
Physical Characteristics
Housing: ABS + PC, IP30 protected
Weight: 150 ± 5 g
Dimensions: 27 x 123 x 79 mm (1.06 x 4.84 x 3.11 in)
Environmental Limits
Operating Temperature:
G2110/2150I: 0 to 55°C (32 to 131°F)
G2110-T: -30 to 75°C (-22 to 167°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 75°C (-40 to 167°F)
Power Requirements
Input Voltage: 12 to 48 VDC
Power Consumption:
Idle: 50 mA @ 12 V
Data Link: 300 to 900 mA (peak) @ 12 V
Regulatory Approvals
EMC: CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B 
Class A
RF: FCC Part 22H, FCC Part 24E, EN301 489-1, EN301 489-7, 
EN301 511
The certifi cation logos shown here apply to some or all 
of the products in this section. Please see the Specifi ca-
tions
 section or Moxa’s website for details.