Graupner Hendheld RC 2.4 GHz No. of channels: 8 33116 Data Sheet
Product codes
33116
76
Program description: base settings - fixed-wing model
when the servo position first falls below the switching
threshold (max. +150%).
The speed controller or throttle servo remains at
this motor OFF position until you operate the select-
ed switch again, and use the throttle / brake stick to
move the throttle servo or speed controller beyond
the pre-programmed switching threshold.
threshold (max. +150%).
The speed controller or throttle servo remains at
this motor OFF position until you operate the select-
ed switch again, and use the throttle / brake stick to
move the throttle servo or speed controller beyond
the pre-programmed switching threshold.
The default value in the left-hand column for the “motor
OFF” position of the throttle servo is -100%; the default
switching threshold in the centre column is a servo posi-
tion of +150%:
OFF” position of the throttle servo is -100%; the default
switching threshold in the centre column is a servo posi-
tion of +150%:
mod name
stick mode
motor at C1
1
idle re.
tail type
normal
GRAUBELE
cut off
–––
+150%
–100%
STO
Programming
This is the procedure for changing the default value for
the “motor OFF” position of the throttle servo: briefly
press the central
This is the procedure for changing the default value for
the “motor OFF” position of the throttle servo: briefly
press the central
SET
button of the right-hand touch-key:
the current setting is now highlighted (dark background).
Now use the arrow buttons of the left or right-hand
touch-key to enter a value at which the motor is reliably
“off”. If you are controlling a throttle servo (carburettor)
it is important to ensure that the throttle servo does not
strike its mechanical end-stop, e.g. -125%:
Now use the arrow buttons of the left or right-hand
touch-key to enter a value at which the motor is reliably
“off”. If you are controlling a throttle servo (carburettor)
it is important to ensure that the throttle servo does not
strike its mechanical end-stop, e.g. -125%:
mod name
stick mode
motor at C1
1
idle re.
tail type
normal
GRAUBELE
cut off
–––
+150%
STO
–125%
The default value in the centre column is deliberately
high, as this enables you to stop the motor over the
maximum possible range of servo travel (or speed con-
troller range) simply by operating the switch; the switch
is assigned in the right-hand column later.
However, if you prefer to set a lower switching threshold,
so that the switch only takes effect when the throttle
servo or speed controller is below a certain point, then
you should reduce the pre-set servo travel from +150%.
This is accomplished by moving the throttle / brake
stick until the throttle servo or speed controller is at the
position you prefer, then briefly pressing the central
high, as this enables you to stop the motor over the
maximum possible range of servo travel (or speed con-
troller range) simply by operating the switch; the switch
is assigned in the right-hand column later.
However, if you prefer to set a lower switching threshold,
so that the switch only takes effect when the throttle
servo or speed controller is below a certain point, then
you should reduce the pre-set servo travel from +150%.
This is accomplished by moving the throttle / brake
stick until the throttle servo or speed controller is at the
position you prefer, then briefly pressing the central
SET
button of the right-hand touch-key:
mod name
stick mode
motor at C1
1
idle re.
tail type
normal
GRAUBELE
cut off
–––
+100%
STO
–125%
The final step is to move to the right-hand column
and assign a switch which you would like to use to cut
the motor (in an emergency) or activate the switching
threshold.
and assign a switch which you would like to use to cut
the motor (in an emergency) or activate the switching
threshold.
mod name
stick mode
motor at C1
1
idle re.
tail type
normal
GRAUBELE
cut off
+100%
STO
–125%
9
Notes:
You must ensure that the throttle servo does not
•
strike its mechanical end-stop when the motor stop
switch is operated.
To set a switching threshold higher than +100%, tem-
switch is operated.
To set a switching threshold higher than +100%, tem-
•
porarily increase the travel of servo 1 to more than
100% in the “Servo settings” menu, and then restore
the original value once you have stored the switch-
ing threshold.
100% in the “Servo settings” menu, and then restore
the original value once you have stored the switch-
ing threshold.
tail type
mod name
stick mode
motor on C1
1
idle re.
tail type
normal
GRAUBELE
cut off
+100%
–125%
9
When you select “tail type” using the arrow buttons
of the left or right-hand touch-key, you will see
the corresponding input field framed. Touch the central
SET
button of the right-hand touch-key to highlight the
current setting. Now use the arrow buttons of the right-
hand touch-key to select the option which matches your
model:
hand touch-key to select the option which matches your
model:
„normal“:
This setting caters for all models in which
each of the functions elevator and rudder