Jeti Hendheld RC 2.4 GHz No. of channels: 8 80001586 User Manual

Product codes
80001586
Page of 164
computer radio control system
EN
3.
3.
Each  receiver  channel  can  be  configured  to  one  of  the  modes 
described above. We recommend that you setup „fail safe“ positions 
for  every  output,  which  enables  your  model  to  stay  in  a  stable 
condition. For instance, the elevator and rudder in neutral positions, 
electric motor switched-off, gas engine idling, spoilers extended.
Configuration Method of the receiver failsafe function.
1.
 
Bind receiver with transmitter. See chapter: 8.4 Binding. Leave 
receiver and transmitter in switched-on condition.
2. 
In  the  transmitter,  go  to  the  menu  „System->JETIbox“  and 
proceed according to picture.   Use the F1-F4 function buttons to 
move within the menu.
3. 
In the „Set Output Pin“ menu select the receiver output which 
you want to configure (use the left/right buttons) and proceed (by 
using the down-button).
4. 
In the „Signal Fault Yn“ menu where n denotes the channel 
number which has to be configured, use the right-button to edit the 
output function showing a signal failure (setup „fail safe“).  You have 
now activated the „fail safe“ function on receiver channel output n.
5. 
The „fail safe“ is adjusted by pressing the down-button and 
changing to the „fail safe“ menu. With the left/right buttons edit the 
„fail  safe“  value  in  a  range  of  0.8ms  to  2.2  ms.  Adjust  all  of  the 
connected receiver outputs by repeating steps 3-5.
The last parameter to be set up is the elapsed time after signal failure 
when  the  „fail  safe“  or  other  actions  after  signal  failure  will  be 
initiated. In the „SignalFault Delay“ menu you can define the length 
of time after a signal fault occurrs in which the preset   throws are 
applied.  The  values  in  this  menu  are  changed  by  pressing  the 
left/right buttons.
57