Jeti Hendheld RC 2.4 GHz No. of channels: 8 80001586 User Manual
Product codes
80001586
computer radio control system
EN
3.
3.
1.
The list of active commands.
2.
Sa switch is assigned to reset
minimums, maximums, and the measured
capacity. For the reset command only the
Control mode is available (the position of
the control/switch is taken as an input),
other devices may accept a proportional
value specified as a constant or as the
channel number on the transmitter.
capacity. For the reset command only the
Control mode is available (the position of
the control/switch is taken as an input),
other devices may accept a proportional
value specified as a constant or as the
channel number on the transmitter.
3.
Scroll to view minimums and maximums.
4.
Pushing the „3D” button enables you to
add the command into the list of active
commands and it is possible to assign a
transmitter control to it.
commands and it is possible to assign a
transmitter control to it.
On the main screen of the Central Box settings scroll down to display
the maximum telemetry values (Telemetry Min/Max). Here you will
find a choice to assign a switch to the command for deleting
measured minimums and maximums (Clear Min/Max switch).
Pushing the „3D” button on this item you are moved to the list of
active commands where this command is already listed and is
inversely highlighted with a cursor.
the maximum telemetry values (Telemetry Min/Max). Here you will
find a choice to assign a switch to the command for deleting
measured minimums and maximums (Clear Min/Max switch).
Pushing the „3D” button on this item you are moved to the list of
active commands where this command is already listed and is
inversely highlighted with a cursor.
Pushing the „3D” button moves you to the choice to assign the
control/switch that will further on take care of the command for
resetting. Here we have chosen the Sa switch.
control/switch that will further on take care of the command for
resetting. Here we have chosen the Sa switch.
Further operation of the command will look like this:
- Moving the Sa switch into the ON position makes the transmitter
detect that it should send the command for resetting telemetry
minimums and maximums to the model. However, before the
command is applied, it is necessary to confirm the choice by the pilot
to avoid unwanted resetting of the data.
detect that it should send the command for resetting telemetry
minimums and maximums to the model. However, before the
command is applied, it is necessary to confirm the choice by the pilot
to avoid unwanted resetting of the data.
- The transmitter displays a dialog asking if you want to execute the
command for resetting the telemetry. If you press NO or you do not
manage to respond in time, the dialog closes and the command is
not executed.
command for resetting the telemetry. If you press NO or you do not
manage to respond in time, the dialog closes and the command is
not executed.
- Conversely, if you press YES, the command is sent to the model
where it is processed by the Central Box which resets its telemetry.
The result of this command can be displayed on the main screen of
the transmitter in the telemetry window – the item Capacity of the
Central Box will now be set to zero.
where it is processed by the Central Box which resets its telemetry.
The result of this command can be displayed on the main screen of
the transmitter in the telemetry window – the item Capacity of the
Central Box will now be set to zero.