Program description: base settings - fi xed-wing model
timer
Two timers are shown in the basic display: one stop-
watch and one fl ight timer:
GRAUBELE
#01
0:00h
stop
 flt
0:00
0:00
0.0V
6.1V
HoTT
M
99%
You can assign a physical switch or a control switch to 
these two timers in the right-hand column of the “timer” 
line, indicated by the switch symbol 
 at the bottom 
edge of the screen.
motor  at  C1
idle  re.
tail  type
nor mal
cut  off
+100%
–125%
1
aile/flap
2aile
timer
0:00
–––
The assigned switch starts both timers, and also halts 
the stopwatch.
The method of assigning a physical switch or a control 
switch is described on page 39.
The fl ight timer, and the saving of telemetry data on 
a memory card fi tted in the card slot (see page 22), 
always starts simultaneously with the stopwatch, but 
continues to run even when the stopwatch is halted 
(switched off). It can only be stopped by pressing the 
central 
ESC
 button of the left-hand four-way button 
when the stopwatch is already halted.
Once the timers are stopped, you can reset both timers 
to their initial value by simultaneously pressing the 
cd 
or 
ef buttons of the right-hand key (CLEAR).
Switching between “count-up” and “count-down”
Count-up timer (stopwatch function)
If you assign a switch and start the stopwatch with the 
initial value of “0:00”, the timer runs up until the maxi-
mum of 180 minutes and 59 seconds, then re-starts at 
0:00.
Count-down timer (alarm timer function)
You can select a starting time within the range 0 to 180 
minutes in the left-hand minutes fi eld, and a starting 
time within the range 0 to 59 seconds in the right-hand 
seconds fi eld. Any combination of times can also be 
selected.
Simultaneously pressing the 
cd or ef buttons of the 
right-hand four-way button (CLEAR) resets any settings 
you have made to “0” or “00”.
motor  at  C1
idle  re.
tail  type
nor mal
cut  off
+100%
–125%
1
aile/flap
2aile
timer
0:00
3
Procedure
Select the desired input fi eld using the arrow buttons 
1. 
ef of the left or right-hand four-way button.
Press 
2. 
SET
 in the centre of the right-hand four-way 
button.
Select the required time in the highlighted minutes 
3. 
and seconds fi elds using the arrow buttons of the 
right-hand four-way button.
Press the central 
4. 
SET
 button to conclude the input 
process.
Once you have switched back to the basic display 
5. 
by pressing the central 
ESC
 button of the left-hand 
four-way button the required number of times, press 
the 
cd or ef buttons of the right-hand four-way 
button (CLEAR) simultaneously, with the stopwatch 
stopped, to switch the stopwatch to the “Timer” func-
tion; see top right in the following illustration:
GRAUBELE
#01
0:00h
stop
 flt
10:01
0:00
0.0V
6.1V
HoTT
M
99%
When you operate the assigned switch, the stopwatch 
now starts from the set initial value, counting down 
(“Timer function”). When the set time has elapsed, the 
timer does not stop, but continues to run so that you can 
read off the time elapsed after reaching zero. To make 
this clear, the over-run time is shown highlighted (black 
background).
Sequence of sounds
30 sec. before zero:  triple beep
 
single beep every two seconds
20 sec. before zero:  double beep
 
single beep every two seconds
10 sec. before zero:  single beep
 
single beep every second
  5 sec. before zero:  single beep every second at higher 
rate
zero:  longer beep; display switches to 
inverse video