EN
Message Codes
If the message Error does not disappear 
after switching on the device repeatedly, 
contact the dealer.
If the message InFo appears with a number, 
press the Clear button and observe the 
following instructions:
Care
• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents or 
solvents.
Warranty
Lifetime Manufacturer's Warranty
Warranty coverage for the entire usage time 
of the product according to Leica Geosys-
tems International Limited Warranty. Free of 
charge repair or replacement for all products 
that suffer defects as a result of faults in mate-
rials or manufacturing, for the entire life of 
the product.
3 Years no Cost
Guaranteed service should the product 
become defective and require servicing 
under normal  conditions of use, as described 
in the user manual, at no additional charge.
To receive the "3 years no cost" period, the 
product must be registered at www.leica-
geosystems.com/registration within 8 weeks 
of the purchase date. If the product is not 
registered, a "2 years no cost" period applies. 
Safety Instructions
The person responsible for the instrument 
must ensure that all users understand these 
directions and adhere to them.
Areas of responsibility
Responsibilities of the manufacturer 
of the original equipment: 
Leica Geosystems AG
Heinrich-Wild-Strasse
CH-9435 Heerbrugg
Internet: www.disto.com
The company above is responsible for 
supplying the product, including the User 
Manual in a completely safe condition.
The company above is not responsible for 
third party accessories.
Responsibilities of the person in 
charge of the instrument:
• To understand the safety instructions on 
the product and the instructions in the 
User Manual.
• To be familiar with local safety regulations 
relating to accident prevention.
• Always prevent access to the product by 
unauthorised personnel.
No.
Cause
Correction
156
Transverse tilt greater 
than 10°
Hold the instrument 
without any transverse tilt.
162
Calibration mistake
Make sure, the device is 
placed on a absolutely 
horizontal and flat surface. 
Repeat the calibration 
procedure. If the mistake 
still occurs, contact your 
dealer.
204
Calculation error
Perform measurement 
again.
240
Data transfer error
Repeat procedure.
252
Temperature too high Let device cool down.
253
Temperature too low Warm device up.
255
Received signal too 
weak, measuring time 
too long
Change target surface 
(e.g. white paper).
256
Received signal too 
high
Change target surface 
(e.g. white paper).
257
Too much back-
ground light
Shadow target area.
258
Measurement outside 
of measuring range
Correct range.
260
Laser beam inter-
rupted
Repeat measurement.