7. Technical Data
Accuracy
Standard deviation for 1 km double levelling 
ISO17123-2:
Jogger 20 .............................................2.5 mm
Jogger 24/28/32 ...................................2.0 mm
Telescope
Erect image
Magnification: 
Jogger 20 .................................................. 20 x
Jogger 24 .................................................. 24 x
Jogger 28 .................................................. 28 x
Jogger 32 .................................................. 32 x
Field of view at 100 m ..........................< 2.1 m
Shortest target distance
from instrument axis.............................< 1.0 m
Distance measurement
Multiplication factor ....................................100
Additive constant............................................0
Compensator
Working range ..........................................± 15'
Setting accuracy
(standard deviation) ................................... 0.5"
Circular level
Sensitivity...........................................8' / 2 mm
Circle
Graduation ................................................360°
Graduation interval .......................................1°
Adaption
To normal or ball head tripod
Central fixing screw  .................................. 5/8"
Temperature range
Storage ..................................- 30°C to + 55°C
............................................. (-22°F to +131°F)
Operating ...............................- 20°C to + 40°C
............................................... (-4°F to +102°F)
Environmental conditions
Water and dust proof.....................IP54 (IEC60529)