Cep Terminals 6201 GSM Remote Switch Control Module 6201 Data Sheet

Product codes
6201
Page of 32
CEP AG 
 
Revision 1.4 
 
_________________________________________________________________________________ 
__________________________________________________________________________________________   
 
 
 
Page 12 of 32 
 
3.2  Switching OFF the modem 
 
There are two ways to switch off (power down) the modem as described below: 
 
 use the 
“AT^SMSO” command 
 EMERG_OFF to high level for t < 1s 
 
A delay of up to 10s is experienced as the modem logs off the network 
 
3.3  Operating states / LEDs 
 
3.3.1 
Power up LED (green LED in the middle) 
 
The modem has a green power up LED, as depicted below, which is used to indicate 
various operating states. These states are described in following table.
 
 
Operating state of CT63 Terminal 
Power up LED 
state 
Device off 
Permanently off 
net search / not registered /  
Fast blinking 
registered full service 
Slow blinking 
A call is active 
Permanently on 
 
 
4  Power consumption 
 
The following table shows you the power consumption of the CT63 / in different 
modes: 
 
CT63 Terminal 
 
[mA] @ 5V 
[mA] @ 12V  [mA] @ 24V  [mA] @ 32V 
CT63 off (DTR low, no TO-IN)  
0,04 
0,11 
0,22 
0,29 
CT63 idle mode 
24,0 
11,1 
6,2 
5,5 
CT63 low power mode 
3,0 
1,1 
1,0 
0,9