  With  the  command  “PN:<4digit  password>.”  the  password  can  be  changed.  The  password  can 
include letters and figures but special characters are  not allowed. All letters have to be in capital. 
The standard password (factory setting) is 9851. 
  The  texts  of  the  event  or  start-up  SMS  can  be  changed  with  the  commands  “E1:<text1>.”, 
“E2:<text2>.”… and “PT:<startup text>.”. The message length must not exceed 64 characters. Do not 
use command syntax inside a message text. The ‘.’ is the terminating character of the text. Each new 
text must be sent in a separate SMS. 
  You can generate an extended clip list of 1000 clip numbers. The numbers stored in the clip list are 
allowed to switch relay 1 with a phone call. Use “CL:” to generate the clip list and add further phone 
numbers. With “CD:” you can delete a phone number from the list. Be aware that you cannot read 
out  the  clip  list  (getting  SMS  messages)  because  it could  by  far  exceed  the  size  limitation  of  SMS 
texts. 
  With the command “TOx:<text>.” (x = 1 to 10, see command list above) an email address for the 
particular events is configured. 5 email Adresses can be configured, divided by <;>. 
The maximum length of the particular email addresses is 25 signs. 
  With the command “SUBx:<text>.” (x=1 to 10, see command list above) the subject of the particular 
emails is configured. The maximum number of sings for the subject is 128 signs. The predefined text 
is: “STD35 Event x”. 
  The content of the Email is configured with “BODY:<text>.”. The maximum length is 143 signs. 
  The email sender address (of the STD35) is changed with “FROM:<text>.”. The maximum length is 
25 signs. 
 
Please note that all commands listed in the section “Configuration SMS” require the 4-digit keyword at 
the beginning. 
 
7.5 
Examples of SMS Commands
 
Start-up  alarm  off,  relay  1  on,  relay  2  off, 
time of activation of input 1: 5 sec 
9851 
S:0.O1ON.O2OFF.I1:5. 
Switching time of relay 1 = 90 seconds 
9851 O1:90. 
Reset settings to factory settings 
9851 R: 
Configuration of the second alarm number 
9851 C2:+491721234567. 
Deleting a alarm number 
9851 C2:"". 
Configuration of a new password 
9851 PN:AB12. 
Adding a new clip to the extended clip list 
9851 CL:+491721234567. 
Removing  the  clip  from  the  extended  clip 
list: 
9851 CD:+491721234567. 
Table 9: SMS Commands