Cep Terminals 04100 GSM Remote Switch Control Module 04100 Data Sheet
Product codes
04100
18
With the command “PN:<4digit password>.” the password can be changed. The password can
include letters and figures but special characters are not allowed. All letters have to be in capital.
The standard password (factory setting) is 9851.
The standard password (factory setting) is 9851.
The texts of the event or start-up SMS can be changed with the commands “E1:<text1>.”,
“E2:<text2>.”… and “PT:<startup text>.”. The message length must not exceed 64 characters. Do not
use command syntax inside a message text. The ‘.’ is the terminating character of the text. Each new
text must be sent in a separate SMS.
use command syntax inside a message text. The ‘.’ is the terminating character of the text. Each new
text must be sent in a separate SMS.
You can generate an extended clip list of 1000 clip numbers. The numbers stored in the clip list are
allowed to switch relay 1 with a phone call. Use “CL:” to generate the clip list and add further phone
numbers. With “CD:” you can delete a phone number from the list. Be aware that you cannot read
out the clip list (getting SMS messages) because it could by far exceed the size limitation of SMS
texts.
numbers. With “CD:” you can delete a phone number from the list. Be aware that you cannot read
out the clip list (getting SMS messages) because it could by far exceed the size limitation of SMS
texts.
With the command “TOx:<text>.” (x = 1 to 10, see command list above) an email address for the
particular events is configured. 5 email Adresses can be configured, divided by <;>.
The maximum length of the particular email addresses is 25 signs.
The maximum length of the particular email addresses is 25 signs.
With the command “SUBx:<text>.” (x=1 to 10, see command list above) the subject of the particular
emails is configured. The maximum number of sings for the subject is 128 signs. The predefined text
is: “STD35 Event x”.
is: “STD35 Event x”.
The content of the Email is configured with “BODY:<text>.”. The maximum length is 143 signs.
The email sender address (of the STD35) is changed with “FROM:<text>.”. The maximum length is
The email sender address (of the STD35) is changed with “FROM:<text>.”. The maximum length is
25 signs.
Please note that all commands listed in the section “Configuration SMS” require the 4-digit keyword at
the beginning.
7.5
Examples of SMS Commands
Start-up alarm off, relay 1 on, relay 2 off,
time of activation of input 1: 5 sec
time of activation of input 1: 5 sec
9851
S:0.O1ON.O2OFF.I1:5.
Switching time of relay 1 = 90 seconds
9851 O1:90.
Reset settings to factory settings
9851 R:
Configuration of the second alarm number
9851 C2:+491721234567.
Deleting a alarm number
9851 C2:"".
Configuration of a new password
9851 PN:AB12.
Adding a new clip to the extended clip list
9851 CL:+491721234567.
Removing the clip from the extended clip
list:
list:
9851 CD:+491721234567.
Table 9: SMS Commands